319877

EFFECT OF USING IMAGE STANDARDIZATION DEVICE FOR DENTAL PHOTOGRAPHY STANDARDIZATION IN COMPARISON TO INDIVIDUALIZED PHOTOGRAPHY: IN VIVO STUDY

Article

Last updated: 03 Jan 2025

Subjects

-

Tags

-

Abstract

This RCT aimed to evaluate the effect of Image Standardization Device (ISD) on standardization of clinical images from the same entry point.

The methodology of the current study included a total of twenty patients, photographed with ISD taking duplicate photographs and using individualized photography as a control group via conventional Tripod from the same photography point at 45º from the patient's right side to study the effect of the image standardization device in photograph standardization over conventional imaging methods.

The Intervention used in this study was bleaching that was done before taking the same photographs once again from the same projections to reproduce the same images using both methods.

The assessment was done by measuring in millimeters the horizontal and vertical measurements of the canine in each patient by using a ruler tool on digital software and comparing them with the reference standard which was the canine's pre-treatment measurements.

The results showed no statistically significant change in the ISD group regarding the mean canine horizontal & vertical measurement while there was a statistically significant difference in the same measurement in the Tripod group in the before compared to after treatment measures.

This study concluded that ISD is capable of producing perfectly standardized images each time they're taken by the device from the same position and entry point with minimal effort and time consumption, while the Tripod resulted in standard but yet not perfect photographs.

DOI

10.21608/adjc.2023.212769.1323

Keywords

replication, pictures, Documentation

Authors

First Name

Nourhan

Last Name

Hussein

MiddleName

Ashraf

Affiliation

Department of operative dentistry, Faculty of dentistry, Cairo University, Cairo, Egypt

Email

nanabakr189@gmail.com

City

-

Orcid

-

First Name

Mohamed

Last Name

Abdel Mohsen

MiddleName

Mahmoud

Affiliation

Department of operative dentistry, Faculty of dentistry, Cairo University, Cairo, Egypt

Email

mmohsen52@yahoo.com

City

cairo

Orcid

-

Volume

5

Article Issue

4

Related Issue

43727

Issue Date

2023-10-01

Receive Date

2023-05-31

Publish Date

2023-10-01

Page Start

715

Page End

722

Print ISSN

2636-302X

Online ISSN

2636-3038

Link

https://adjc.journals.ekb.eg/article_319877.html

Detail API

https://adjc.journals.ekb.eg/service?article_code=319877

Order

319,877

Type

Review Article

Type Code

691

Publication Type

Journal

Publication Title

Advanced Dental Journal

Publication Link

https://adjc.journals.ekb.eg/

MainTitle

EFFECT OF USING IMAGE STANDARDIZATION DEVICE FOR DENTAL PHOTOGRAPHY STANDARDIZATION IN COMPARISON TO INDIVIDUALIZED PHOTOGRAPHY: IN VIVO STUDY

Details

Type

Article

Created At

24 Dec 2024