Beta
285517

Comparison between Plasma gel (Filler) and Polydiaxone (PDO) Threads in Treating Fine and Medium Sized Infra-Orbital Wrinkles Using 3D Antera Camera

Article

Last updated: 03 Jan 2025

Subjects

-

Tags

-

Abstract

Background: Plasma gel is a new procedure in the aesthetic field. It has been used for various dermatological conditions including wound healing, anti-inflammatory, and cosmetic uses. Infra-orbital dark circles possess no medical harm but signifies cosmetic and psychological burden. Objective: Evaluation the efficacy and safety of plasma gel (Filler) injection and comparing its result with polydiaxone (PDO) mono threads in peri-orbital rejuvenation by subjective measure using a 3D computerized camera which gives a report with very fine details. Patients and methods: 40 patients with infra-orbital fine wrinkles were included and by the Antera 3D camera, these fine wrinkles were divided to small sized and medium sized wrinkles and evaluated for the changes in the size and depth, indentation index and texture roughness of the wrinkles. Patients underwent plasma gel injections into the infra-orbital area of the left eye and PDO mono threads insertion in the right side. All patients were evaluated using the Antera camera at day (0m), after one month (1m) and after 6 months (6m) of the therapy. Results: Antera reports of the side injected with the plasma gel showed very good response. Also PDO mono threads insertion revealed marked cosmetic results, yet the efficacy of the plasma filler was superior as regards wrinkle's size, indentation index and texture roughness. .  

DOI

10.21608/ejhm.2023.285517

Keywords

Infra-orbital fine wrinkles, 3D Antera camera, Plasma gel, PDO thread

Authors

First Name

Samah Ibrahim

Last Name

Hassen

MiddleName

-

Affiliation

-

Email

drsamah81@yahoo.com

City

-

Orcid

-

First Name

Heba Mahmoud El-Sayed

Last Name

Diab

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Wassan Mohammed Jwad

Last Name

Zayed

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Ahmed F.

Last Name

Elhawatky

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

Volume

90

Article Issue

2

Related Issue

39562

Issue Date

2023-01-01

Receive Date

2023-02-14

Publish Date

2023-01-01

Page Start

2,231

Page End

2,241

Print ISSN

1687-2002

Online ISSN

2090-7125

Link

https://ejhm.journals.ekb.eg/article_285517.html

Detail API

https://ejhm.journals.ekb.eg/service?article_code=285517

Order

34

Type

Original Article

Type Code

606

Publication Type

Journal

Publication Title

The Egyptian Journal of Hospital Medicine

Publication Link

https://ejhm.journals.ekb.eg/

MainTitle

Comparison between Plasma gel (Filler) and Polydiaxone (PDO) Threads in Treating Fine and Medium Sized Infra-Orbital Wrinkles Using 3D Antera Camera

Details

Type

Article

Created At

24 Dec 2024