Beta
283341

PASSIVITY OF SCREW-RETAINED IMPLANT-SUPPORTED PEEK FRAMEWORKS USING SEGMENTED VERIFICATION JIGS VERSUS CONVENTIONAL JIGS-FREE TECHNIQUES UTILIZING OPEN-TRAY IMPRESSION PROCEDURES

Article

Last updated: 23 Dec 2024

Subjects

-

Tags

-

Abstract

Purpose: This comparative study aimed to assess if there was a difference in clinical & radiographic outcomes of a maxillary
screw-retained implant-supported prosthesis constructed from PEEK regarding the effect of utilizing the segmented verification
jig technique.
Material and methods : In this clinical investigation, fourteen patients with edentulous maxillary ridges carefully chosen
having adequate amounts and qualities of bone. There were two groups of patients; Group I (seven patients) received an
Implant-supported screw-retained full arch maxillary prosthesis with a delayed functional loading protocol utilizing 6 implants,
where, an open-tray impression technique was applied and the prosthesis PEEK without utilizing verification jig, while Group II
(seven patients) received same prosthesis BUT with segmented verification jig technique. The radiographic outcomes measured
at the time of prosthesis insertion, 6 months, one year& two years, respectively & clinical outcome represented as patients'
satisfaction measured utilizing a customized chart of the questionnaire (VAS).
Results : The several repetitions of the two groups were compared using the ANOVA test, which was also used to examine
the changes over time within each group. Pair-wise comparisons made using Tukey's post-hoc test where the ANOVA test was
significant. Clinical patients' satisfaction was measured using a visual analogue scale (VAS) and a separate t-test for a direct
comparison of the two groups. Different intervals were significant for each group, with a p-value of 0.001.
Conclusion: Achieving optimal passivity of the PEEK framework claimed through segmented verification jig manuver
developed an advantageous response in terms of radiography outcomes as well as patient satisfaction.

DOI

10.21608/OMX.2022.167769.1171

Keywords

dental implant, Verification jigs, screw-retained prosthesis, Delayed functional loading, PEEK frameworks

Authors

First Name

Mostafa

Last Name

Ahmed

MiddleName

-

Affiliation

Assistant Professor Prosthodontics Department-Faculty of Dentistry Cairo University

Email

-

City

-

Orcid

-

First Name

Enas

Last Name

Darwish

MiddleName

-

Affiliation

Assistant Professor Prosthodontics Department-Faculty of Dentistry Cairo University

Email

-

City

-

Orcid

-

Volume

13

Article Issue

3

Related Issue

39326

Issue Date

2022-07-01

Receive Date

2022-10-08

Publish Date

2022-07-01

Page Start

126

Page End

136

Print ISSN

2090-097X

Online ISSN

2090-5424

Link

https://omx.journals.ekb.eg/article_283341.html

Detail API

https://omx.journals.ekb.eg/service?article_code=283341

Order

283,341

Type

Original Article

Type Code

506

Publication Type

Journal

Publication Title

Egyptian Journal of Oral and Maxillofacial Surgery

Publication Link

https://omx.journals.ekb.eg/

MainTitle

PASSIVITY OF SCREW-RETAINED IMPLANT-SUPPORTED PEEK FRAMEWORKS USING SEGMENTED VERIFICATION JIGS VERSUS CONVENTIONAL JIGS-FREE TECHNIQUES UTILIZING OPEN-TRAY IMPRESSION PROCEDURES: 2 years clinical & radiographic outcomes

Details

Type

Article

Created At

23 Dec 2024