This study aimed to examine the benefits and drawbacks of both solid phase and liquid phase radioimmunoassays (RIA) used to quantify C-peptide in human serum. Three fundamental reagents were made. The first RIA tracer was 125I-C-peptide. Its indirect preparation utilized chloramine-T and tyrosine methyl ester (TME). Using an HPLC column, the tracer was cleaned. The second one was the polyclonal antibodies which were produced in other work previously. The coated process using coated tube was carried out. Thirdly, using highly purified C-peptide, a set of standards was created. A liquid phase system radioimmunoassay (RIA) was created to measure C-peptide levels in human serum. Numerous elements were investigated, including cross reaction, specific and nonspecific binding, sample volume, temperature influence, incubation time, and validity period. Different samples of human serum were determined using both methods. The statistical study showed strong connections between the outcomes of the two procedures, but there were minor differences. The solid phase has many advantages than other one. A high nonspecific binding and a low specific binding percent were observed. A high binding percent and the low cost are the main advantages in Liquid phase system.

DOI

10.21608/ajnsa.2023.183282.1701

Keywords

C-peptide, RIA, 125I, Liquid phase, Solid phase, HPLC

Authors

First Name

Ahmed

Last Name

Abdelsadek

MiddleName

Ali

Affiliation

Isotopes and radio generators Dep. Hot Labs. Center, EAEA

Email

aasadek73@gmail.com

City

-

Orcid

-

First Name

Prof. Khaled

Last Name

SALLAM

MiddleName

Mohamed

Affiliation

Isotopes and radio generators Dep. Hot Labs. Center, EAEA

Email

drkhaledsallam71@gmail.com

City

CAIRO

Orcid

-

First Name

Mahmoued

Last Name

eltawoosy

MiddleName

-

Affiliation

Isotopes and radio generators Dep. Hot Labs. Center, EAEA

Email

m_eltawoosy@yahoo.com

City

Cairo

Orcid

-

Volume

56

Article Issue

4

Related Issue

42139

Issue Date

2023-07-01

Receive Date

2022-12-25

Publish Date

2023-07-01

Page Start

101

Page End

106

Print ISSN

1110-0451

Online ISSN

2090-4258

Link

https://ajnsa.journals.ekb.eg/article_305449.html

Detail API

https://ajnsa.journals.ekb.eg/service?article_code=305449

Order

305,449

Type

Original Article

Type Code

455

Publication Type

Journal

Publication Title

Arab Journal of Nuclear Sciences and Applications

Publication Link

https://ajnsa.journals.ekb.eg/

MainTitle

Comparative study between liquid phase and solid phase radioimmunoassay system for determination of C-pipted in human serum

Details

Type

Article

Created At

23 Dec 2024