Abstract

Abstract
Background: The measurement of blood alcohol levels is a routine analysis carried out in many forensic laboratories. Headspace and Solid-Phase Micro-Extraction techniques coupled with Gas Chromatography have emerged as the method of choice for alcohol detection in blood samples, which is too expensive and unavailable in most clinical laboratories in developing countries.

Aim: The objective of this study was to validate and develop an efficient and sensitive Gas Chromatography-Flame Ionization Detector (GC-FID) analytical method for detecting and quantifying methyl and ethyl alcohol in blood by solvent partitioning extraction technique without the need for Headspace techniques.

Methods: Analysis was performed on sheep's whole blood using chloroform as the extracting solvent and dichloromethane as the internal standard. Linearity was achieved across a concentration range of 10 mg to 320 mg/dl for methanol and ethanol. The developed method was fully validated according to the guidelines of the Scientific Working Group for Forensic Toxicology.

Results: The linearity of the method showed a correlation coefficient of 0.999 and 0.998 for whole-blood methanol and ethanol, respectively. The limit of quantification (LOQ) and limit of detection (LOD) were within the range of 7.2–10 mg/dl and 4.0–8.0 for methanol and ethanol in whole blood, respectively, and resulted in a precision of 1.17–6.5 and 0.79–2.98 and an accuracy of 1.07–5.27% and 0.37–36% for methanol and ethanol, respectively.

Conclusion: This new method was a much more convenient and reliable process to measure methanol and ethanol in whole blood samples by reducing sample pretreatment effort and cost with no need for Headspace techniques.

DOI

10.21608/zjfm.2023.241862.1168

Keywords

Methanol, ethanol, GC-FID, partition coefficient, Partition extraction

Authors

First Name

Mohamed

Last Name

Abdelaziz

MiddleName

Abdelazim

Affiliation

Fellow in biochemistry -chromatography lab in poison control center - Ain Shams University Hospitals

Email

dr.mhmdabdelazim@gmail.com

City

ElKhosos-Qaluobaia

Orcid

0000-0001-5964-8256

Volume

22

Article Issue

1

Related Issue

44792

Issue Date

2024-01-01

Receive Date

2023-10-10

Publish Date

2024-01-01

Page Start

85

Page End

103

Print ISSN

1687-160X

Online ISSN

2536-9849

Link

https://zjfm.journals.ekb.eg/article_331475.html

Detail API

https://zjfm.journals.ekb.eg/service?article_code=331475

Order

5

Type

Original Article

Type Code

402

Publication Type

Journal

Publication Title

Zagazig Journal of Forensic Medicine and Toxicology

Publication Link

https://zjfm.journals.ekb.eg/

MainTitle

A novel validated gas chromatography flame ionization detector method for measuring methanol and ethanol in blood samples using a solvent partitioning extraction technique

Details

Type

Article

Created At

23 Dec 2024