Beta
383408

Effect of Different Curing Times and Intensities on the Performance of Compound Class II Bulk-fill Resin Composite Restorations: An In-Vivo Study

Article

Last updated: 23 Dec 2024

Subjects

-

Tags

Conservative Dentistry

Abstract

Objective: To compare effect of high-intensity (2200 mW/cm2) for 1 s with conventional intensity light-curing (1200 mW/cm2) for 20 s on clinical performance of bulk-fill resin composite restorations in compound class II cavities over 12 months follow-up. Material and methods: A total of 28 class II cavities were randomly restored with bulk-fill resin composite (n=14/group) and cured either with high-intensity (2200 mW/cm2) for 1 s (Intervention) or conventional intensity (1200 mW/cm2) for 20 s (Comparator). Modified USPHS criteria for marginal discoloration, marginal adaptation, secondary caries and postoperative sensitivity were used in the evaluation of restorations at baseline (1 week), 6 and 12 months. Results: There was no statistically significant difference between the two curing protocols at different follow-up intervals as regards the evaluated criteria (P > 0.05). High light intensity (2200 mW/cm2) for 1 s showed more risk (score B) when compared to conventional intensity (1200 mW/cm2) for 20 s, regarding marginal discoloration (RR = 5, P = 0.2851), marginal adaptation (RR = 2, P = 0.3737) and secondary caries (RR = 3, P = 0.4900), except for postoperative sensitivity with no risk for scores B and C (RR = 1, P = 1.0000). Conclusion: High-intensity light-curing (2200 mW/cm2) for 1 s has comparable clinical performance to conventional intensity light-curing (1200 mW/cm2) for 20 s for bulk-fill resin composite restorations in class II cavities.

DOI

10.21608/edj.2024.316384.3183

Keywords

Bulk-fill, conventional light-curing, high-intensity light-curing, I-LED, short exposure time light-curing

Authors

First Name

Roaa

Last Name

Azazy

MiddleName

Mohamed Sabry

Affiliation

MSc. Student, Conservative Dentistry Department, Faculty of Dentistry, Cairo University, Cairo, Egypt

Email

roaa.sabry@dentistry.cu.edu.eg

City

-

Orcid

0009-0007-6023-8642

First Name

Omaima

Last Name

Hamza

MiddleName

Safwat

Affiliation

Professor, Conservative Dentistry Department, Faculty of Dentistry, Cairo University, Cairo, Egypt

Email

omaima.hamza@dentistry.cu.edu.eg

City

Cairo

Orcid

0009-0001-1518-1487

First Name

Shereen

Last Name

Fahim

MiddleName

Essameldein

Affiliation

Lecturer, Conservative Dentistry, Faculty of Dentistry, October 6 University, 6th of October City, Egypt.

Email

shereenessam.dent@o6u.edu.eg

City

-

Orcid

0000-0002-0597-5662

First Name

Zeinab

Last Name

Tolba

MiddleName

Omar

Affiliation

Lecturer, Conservative Dentistry Department, Faculty of Dentistry, Cairo University, Cairo, Egypt

Email

zeinab.omar@dentistry.cu.edu.eg

City

-

Orcid

0000-0002-6573-8394

Volume

70

Article Issue

4

Related Issue

50713

Issue Date

2024-10-01

Receive Date

2024-09-01

Publish Date

2024-10-01

Page Start

4,057

Page End

4,069

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_383408.html

Detail API

https://edj.journals.ekb.eg/service?article_code=383408

Order

383,408

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Effect of Different Curing Times and Intensities on the Performance of Compound Class II Bulk-fill Resin Composite Restorations: An In-Vivo Study

Details

Type

Article

Created At