383404

Evaluation of Microtensile Bond Strength of Artificial Caries Affected Dentin-Adhesive Interface after Using Different Caries Removal Methods (In-Vitro Study)

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

Conservative Dentistry

Abstract

Aim: this study was subjected to investigate the effect of different caries removal methods on immediate and delayed microtensile bond strength of universal adhesives to artificial caries affected dentin.
Materials and methods: 60 anonymous extracted human molar teeth were used in this study. The teeth were mounted into acrylic blocks then the coronal enamel and dentin was removed exposing a flat surface of dentin. Then all the specimens were submitted to a pH-cycling model to simulate artificial caries-affected dentin. Two universal adhesives were used GPDM and 10-MDP containing universal adhesive. Teeth were divided into three groups (n=20) according to the type of caries removal method gp 1: diamond bur, gp 2: smart bur, gp 3: laser. Then each group was further subdivided into two subgroups (n=10) according to the type of universal adhesive used. Half of the specimens from each group were tested for Microtensile bond strength (μTBS) immediately and the other half were tested for (μTBS) after 6 months of storage.
Results: The diamond bur recorded significantly higher values of μTBS than other methods, while smart prep bur recorded the lowest bond strength. 10-MDP containing universal adhesive showed significantly immediate stronger microtensile bond strength but showed non -significant higher bond deterioration in delayed μTBS than GPDM containing universal adhesive
Conclusion: The bond strength changes under various circumstances and at different times between different types of dentin bonding systems and different caries removal methods

DOI

10.21608/edj.2024.320275.3199

Keywords

Keywords: pH cycling method, conservative caries removal methods, universal adhesives, functional monomers

Authors

First Name

Shahenda

Last Name

Khedr

MiddleName

Samir

Affiliation

Lecturer, Operative dentistry department, Faculty of dentistry, Beni Suef University, Egypt

Email

shahysamir2004@gmail.com

City

-

Orcid

0009-0007-8215-9101

First Name

Huda

Last Name

Abed El-Haliem

MiddleName

mohamed

Affiliation

Lecturer of Operative Dentistry, Faculty of Dentistry, Mansoura University, Egypt

Email

drhudataha444@gmail.com

City

Mansoura

Orcid

0000-0001-9408-9242

Volume

70

Article Issue

4

Related Issue

50713

Issue Date

2024-10-01

Receive Date

2024-09-14

Publish Date

2024-10-01

Page Start

4,035

Page End

4,045

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_383404.html

Detail API

https://edj.journals.ekb.eg/service?article_code=383404

Order

383,404

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Evaluation of Microtensile Bond Strength of Artificial Caries Affected Dentin-Adhesive Interface after Using Different Caries Removal Methods (In-Vitro Study)

Details

Type

Article

Created At

23 Dec 2024