Abstract:
Purpose: the goal of this study is to assess the cutting efficiency and cleaning efficiency of Trunatomy, Hyflem CM & 2shape NiTi Rotary files.
Material and methods: A total of thirty human multirooted lower molars were obtained. The teeth were categorized into three groups (n=10) based on the rotary system used. Group 1 was prepared using Trunatomy rotary system, group 2 were prepared using Hyflex CM, and group 3 were prepared using 2shape rotary system. Cutting efficiency was evaluated using CBCT while cleaning ability was evaluated using stereomicrscope. The data was analyzed using Shapiro-Wilk test.
Results: No significant difference was seen among the three rotary files in canal volume change while a significant difference was seen among them in debris percentage where the minumum mean value in Trunatomy group.
Conclusion: the three rotary files showed comparable cutting efficiencies while Trunatomy files showed better cleaning ability than the other rotary systems.

DOI

10.21608/edj.2024.298570.3087

Keywords

Keywords: Trunatomy, Hyflex cm, 2Shape, CBCT, Steriomicroscope

Authors

First Name

Ali

Last Name

Elsonbaty

MiddleName

Ahmed

Affiliation

Master’s degree student of Endodontics, Faculty of Dentistry, Ain shams university

Email

alielsonbaty1994@gmail.com

City

-

Orcid

0009-0005-7573-8127

First Name

shady

Last Name

hussien

MiddleName

ali

Affiliation

Prof. of Endodontics, Faculty of Dentistry, Ain shams university

Email

drshadiali@gmail.com

City

Giza

Orcid

0000000279319158

First Name

Sarah

Last Name

Fahmy

MiddleName

Hossam

Affiliation

Lecturer of Endodontics, Faculty of Dentistry, Ain shams university

Email

sarahfahmy@dent.asu.edu.eg

City

Giza

Orcid

0000-0003-0726-3009

Volume

70

Article Issue

4

Related Issue

50713

Issue Date

2024-10-01

Receive Date

2024-06-24

Publish Date

2024-10-01

Page Start

3,815

Page End

3,822

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_383369.html

Detail API

https://edj.journals.ekb.eg/service?article_code=383369

Order

383,369

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Cutting Efficiency and Cleaning Ability of Three Different Nickel Titanium Rotary Systems (An In vitro study)

Details

Type

Article

Created At

23 Dec 2024