Abstract:
Objectives: In this study, the impact of occlusal adjustment by two different methods (T scan and articulating paper) on the variations in vertical bone height surrounding dental implants retained mandiblar overdenture by Peek bar.
Materials and Methods: 16 male patients whose mandibular and maxillary arches were completely edentulous with an age range above 55 years participated in this study. Both the right and left implants were inserted in canine areas Every patient was fitted with an implant mandibular overdenture retained by a CAD/CAM machined PEEK bar.
The patients were divided into two equal groups depending on the occlusal error detection and adjustment technique: Group I used the T scan III device to identify occlusal problems, At the same time Group II employed articulating paper for occlusal adjustment. During the follow-up period, radiographic evaluation was conducted using a digital periapical radiograph to assess the degree of vertical bone loss surrounding the dental implant.
Results: During the follow-up, it was shown that both groups I and II had increased vertical bone loss. When the two groups were compared collectively, group II showed significantly more vertical bone height alterations surrounding the implants than group I.
Conclusion: Within the limitations of this study, it is possible to conclude that using the T scan III device, as opposed to articulating paper, results in reduced vertical bone loss surrounding the dental implants and facilitates better occlusal adjustment in implant-retained lower overdentures.

DOI

10.21608/edj.2024.292924.3057

Keywords

Dental implants, Overdentures, Milled Bars, CAD/CAM technology, Bone loss

Authors

First Name

Amr

Last Name

Gomaa

MiddleName

Salah el din

Affiliation

Associate Professor, Department of Prosthetic Dentistry, Faculty of Dentistry, Fayoum University, Fayoum, Egyp

Email

amrsalaheldin82@gmail.com

City

cairo

Orcid

0000-0002-8633-193X

First Name

Engy

Last Name

Salam

MiddleName

Ali Abdelhaleem

Affiliation

Associate Professor, Oral Radiology Department, Faculty of Dentistry, Fayoum University

Email

engy.salam@gmail.com

City

Cairo

Orcid

0000-0001-5320-5331

First Name

Nora

Last Name

Abd el kader

MiddleName

Mohamed

Affiliation

Lecturer of Removable Prosthodontics, Ahram Canadian University

Email

nourr5070@gmail.com

City

october

Orcid

0009-0006-3170-1469

First Name

Omayma

Last Name

Mohamad

MiddleName

Ahmad

Affiliation

Lecturer Prosthetic Dentistry Faculty of Dentistry Fayoum University Egypt

Email

omaymaahmad263@gmail.com

City

Giza

Orcid

0000-0001-5516-6188

Volume

70

Article Issue

4

Related Issue

50687

Issue Date

2024-10-01

Receive Date

2024-06-20

Publish Date

2024-10-01

Page Start

3,425

Page End

3,435

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_383119.html

Detail API

https://edj.journals.ekb.eg/service?article_code=383119

Order

383,119

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Radiographic Evaluation Of Alveolar Bone in Mandibular Implant Overdenture Retained by Peek Bar Attachment after Occlusal Adjustment with Two Different Methods (T scan and Articu

Details

Type

Article

Created At

23 Dec 2024