Beta
363804

COMPARATIVE STUDY OF THE RETENTION FORCE BETWEEN TWO RESILIENT ATTACHMENTS IN MANDIBULAR IMPLANT OVERDENTURE (AN INVITRO STUDY)

Article

Last updated: 23 Dec 2024

Subjects

-

Tags

Removable Prosthodontics

Abstract

ABSTRACT
Objectives: This study aimed to compare the retention force of two different attachments namely, locator and resilient telescopic attachment in retaining two implant-assisted mandibular overdenture.
Materials and Methods: Sixteen identical mandibular complete dentures were processed to be attached to a completely edentulous epoxy cast. Two implants were placed in the cast's interforaminal region with the aid of a surgical guide. Dentures were randomly divided into two equal groups to be implant retained by either locator attachment (Group A), or telescopic attachment (Group B) using the direct pickup technique. Using the universal testing machine, a vertically oriented tensile load was applied parallel to the path of insertion until the attachments were detached from the abutments. The maximum load required for detachment (retentive force) was calculated at the baseline and following repeated insertions and removals.
Results: Significant differences were observed in all three-time points (initial time point, after 90 days, and after 180 days) in both attachments. The Locator group had a significantly higher mean in comparison to the Peek telescopic group (p < 0.001).
Conclusions: The locator had better retention than the peek telescopic group according to vertical dislodging forces in all three-time points.

DOI

10.21608/edj.2024.286790.3026

Keywords

Keywords: Locator, telescopic attachment, retentive force, implant-assisted

Authors

First Name

Mohamed

Last Name

Bassiony

MiddleName

Zaki

Affiliation

Lecturer, Prosthodontics Department, Faculty of Dentistry, Pharos University, Alexandria, Egypt

Email

mohamed.zaki@pua.edu.eg

City

Alexandria

Orcid

0000-0002-0357-7062

First Name

Naema

Last Name

Ammar

MiddleName

Ali

Affiliation

Assistant Lecturer, Prosthodontics Department, Faculty of Dentistry, Pharos University, Alexandria, Egypt

Email

naema.ammar@pua.edu.eg

City

Alexandria

Orcid

0000-0001-5787-6810

First Name

Khaled

Last Name

Elsherif

MiddleName

Mahmoud

Affiliation

Postgraduate researcher, Prosthodontics Department, Faculty of dentistry, Pharos University, Alexandria, Egypt

Email

khaledelsherif46@gmail.com

City

Shebin Elkom

Orcid

0009-0005-7798-601x

First Name

Sherif

Last Name

Abd Elhamid

MiddleName

M.

Affiliation

Lecturer, Prosthodontics Department, Faculty of Dentistry, Pharos University, Alexandria, Egypt

Email

sherif.abdelhamid@pua.edu.eg

City

Alexandria

Orcid

0000-0002-5985-417X

Volume

70

Article Issue

3

Related Issue

48886

Issue Date

2024-07-01

Receive Date

2024-05-02

Publish Date

2024-07-01

Page Start

2,615

Page End

2,624

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_363804.html

Detail API

https://edj.journals.ekb.eg/service?article_code=363804

Order

363,804

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

COMPARATIVE STUDY OF THE RETENTION FORCE BETWEEN TWO RESILIENT ATTACHMENTS IN MANDIBULAR IMPLANT OVERDENTURE (AN INVITRO STUDY)

Details

Type

Article

Created At

23 Dec 2024