Abstract

Purpose: This study was conducted to evaluate clinically and radiographically locator R-TX attachments using two different loading protocols for implant-supported mandibular overdenture.
Material and Methods: Thirty edentulous patients (a total of 60 implants) received two implants interformenally in the canine area. Patients were divided randomly (using balanced randomization) into two equal groups in accordance with the loading process utilized to attach the mandibular overdenture. Group I (control): Patients received traditional loading protocol with a mandibular implant overdenture retained in place by two RTx locator attachments (after 3 months from implant placement). Group II (study): Patients received early loading protocol with a mandibular implant overdenture retained in place by two RTx locator attachments (at 6th week after implant placement). No implants were lost in the study. After denture placement (T0), six (T6), and twelve (T12) months later, the peri-implant tissue health [Plaque (PL) and (GI) gingival scores, pocket depth (PD) in mm, and crestal bone loss (CBL) in mm] was assessed.
Results: After one year, no statistically significant difference was found in peri-implant tissue health parameters [(PL), (GI), (PD), and (CBL)] at all observation times and between both groups.
Conclusion: Given the sample size limitations on this study, it is possible to reach the following conclusion: RTx locator is a promising attachment system especially when an early loading protocol is planned to be used regarding peri-implant tissue parameters. More randomized clinical studies are needed to confirm the clinical predictability of Rtx locator attachments.

DOI

10.21608/edj.2024.283008.3016

Keywords

Keywords : implant Overdenture, Rt-x locator, implant loading protocol

Authors

First Name

Samar

Last Name

Ryaad

MiddleName

Mostafa

Affiliation

Researcher of Prosthodontics, Faculty of Dentistry, Mansoura University, Egypt.

Email

samarryaad@gmail.com

City

-

Orcid

0009-0005-2611-7893

First Name

Christine

Last Name

Ibrahim

MiddleName

Raouf

Affiliation

Lecturer of Prosthodontics, Faculty of Dentistry, Mansoura University, Egypt.

Email

christineraouf@mans.edu.eg

City

-

Orcid

0000-0002-6946-284X

First Name

Salah

Last Name

Hegazy

MiddleName

Abdelfattah

Affiliation

Professor of Prosthodontics, Faculty of Dentistry, Mansoura University, Egypt.

Email

salahhegazy_72@mans.edu.eg

City

-

Orcid

0000-0002-0555-3371

Volume

70

Article Issue

3

Related Issue

48886

Issue Date

2024-07-01

Receive Date

2024-05-07

Publish Date

2024-07-01

Page Start

2,581

Page End

2,590

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_363801.html

Detail API

https://edj.journals.ekb.eg/service?article_code=363801

Order

363,801

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Clinical and radiographic evaluation of locator R-Tx attachments for two implants supported mandibular overdenture using two loading protocols; A randomized clinical trial.

Details

Type

Article

Created At

23 Dec 2024