Beta
363794

IN-VITRO RETENTION OF HIGH ARCHED MAXILLARY DENTURES CONSTRUCTED FROM CONVENTIONAL, THERMOFORMED, AND MILLED CAD/CAM RESINS.

Article

Last updated: 23 Dec 2024

Subjects

-

Tags

Removable Prosthodontics

Abstract

Purpose: this study was to evaluate the Retention of high-arched maxillary dentures constructed from conventional, thermoformed, and milled CAD/CAM resins.
Materials and Methods: An edentulous patient with high -arched palate was selected from the outpatient clinic, Department of Prosthetic Dentistry, Faculty of Dentistry, Minia University. The patient was seeking complete denture treatment. Using the master cast of this case; thirty stone casts were duplicated, numbered, and randomly allocated to one of three study groups 10 casts each. Thirty denture bases were constructed from the following materials to be as identical as possible 10 of each of the following material: conventional heat cure resin, thermoformed resin, and milling resin by CAD/CAM. The retention of the produced denture bases was tested using a universal testing machine .Results: The thermoformed group displayed the highest numeric retention mean (5.576 N) followed by CAD/CAM (4.888 N) and conventional method (3.232 N). There were statistically significant differences between all groups. Conclusions: within the limitations of this in vitro study, it may be concluded that: The thermoformed resin may be the most suitable material for high arched palate followed by CAD CAM materials. The conventional technique in this case is less recommended.

DOI

10.21608/edj.2024.268628.2931

Keywords

retention, denture base, conventional, Thermoformed, Milled CAD/CAM Resins

Authors

First Name

abdullah

Last Name

Ahmed

MiddleName

Ismael

Affiliation

B D S, 2015, Faculty of Dentistry, Misr University for Science and Technology, MUST. Teaching assistant, Faculty of Dentistry MUST, Egypt.

Email

elbambyabdullah@gmail.com

City

el giza

Orcid

0009-0007-6506-9585

First Name

Hussein

Last Name

Taha

MiddleName

Abdelhady Hussein

Affiliation

Lecturer of Prosthetic Dentistry, Faculty of Dentistry Minia University, Egypt

Email

dr_hussein_hady@mu.edu.eg

City

Minia

Orcid

0000-0001-9201-2903

First Name

Ahmed

Last Name

abdelazeem

MiddleName

sholkamy

Affiliation

Lecturer of Prosthetic Dentistry, Faculty of Dentistry Minia University, Egypt

Email

sholkamy_ahmad@yahoo.com

City

minia

Orcid

0009-0002-0418-898X

First Name

Dina

Last Name

El talawy

MiddleName

Bahgat

Affiliation

Professor of Prosthetic Dentistry, Faculty of Dentistry, Misr University for Science and Technology, MUST, Egypt.

Email

dinaeltalawy@hotmail.com

City

giza

Orcid

0009-0009-2112-0275

First Name

Emad

Last Name

Tolba

MiddleName

Mohamed

Affiliation

Professor of Prosthetic Dentistry, Mina University and Dean, Faculty of Dentistry, Delta University.

Email

emad.agamy@mu.edu.eg

City

egypt

Orcid

0000-0002-3422-2344

Volume

70

Article Issue

3

Related Issue

48886

Issue Date

2024-07-01

Receive Date

2024-02-08

Publish Date

2024-07-01

Page Start

2,509

Page End

2,517

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_363794.html

Detail API

https://edj.journals.ekb.eg/service?article_code=363794

Order

363,794

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

IN-VITRO RETENTION OF HIGH ARCHED MAXILLARY DENTURES CONSTRUCTED FROM CONVENTIONAL, THERMOFORMED, AND MILLED CAD/CAM RESINS.

Details

Type

Article

Created At

23 Dec 2024