Beta
349175

Comparison of peri-implant bone level in mandibular implant overdenture retained by locator attachment with varying retentive insert materials: A retrospective study

Article

Last updated: 23 Dec 2024

Subjects

-

Tags

Removable Prosthodontics

Abstract

Aim: To compare the effect of nylon versus polyetheretherketone (PEEK) retentive insert of locator attachments on peri-implant bone loss in mandibular implant overdenture.
Materials and methods: Completely edentulous patients, with two implants locator attachment for mandibular overdenture were recalled for this study. Patients were divided into two groups: Group I: overdenture retained by locator attachment using nylon retentive male insert, and Group II: overdenture retained by locator attachment with PEEK retentive male insert. Digital periapical radiographs were conducted to capture images of dental implants using a long-cone paralleling technique. Images taken immediately after loading (baseline) and 24 months after loading were used for this study to measure the vertical bone loss (VBL) and horizontal bone loss (HBL). It was considered statistically significant when P value was less than 0.05.
Results: Twenty-four dental implants were placed in twelve patients aged between 52 and 65 years, comprising 7 men and 5 women. There were no instances of implant loss in either group from the time of placement through prosthetic delivery up to the two-year follow-up period. Group I recorded significant lower VBL than Group II after 24 months of loading (P < .05). On the other hand, there was no significant differences in HBL between the two groups (P > 0.05).
Conclusion: Implant overdentures retained by PEEK insert did cause more peri-implant bone loss when compared to those retained with nylon inserts; however further studies are needed to validate these results.

DOI

10.21608/edj.2024.270724.2949

Keywords

Dental implants, overdenture, Locator attachment

Authors

First Name

Mohamed

Last Name

Said

MiddleName

-

Affiliation

Removable Prosthodontics Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt., Restorative Dentistry and Prosthodontics, College of Dentistry, American University of Iraq – Baghdad, Baghdad, Iraq

Email

msaid2012@mans.edu.eg

City

-

Orcid

0000-0002-7466-5158

Volume

70

Article Issue

2

Related Issue

47036

Issue Date

2024-04-01

Receive Date

2024-02-17

Publish Date

2024-04-01

Page Start

1,791

Page End

1,796

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_349175.html

Detail API

https://edj.journals.ekb.eg/service?article_code=349175

Order

349,175

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Comparison of peri-implant bone level in mandibular implant overdenture retained by locator attachment with varying retentive insert materials: A retrospective study

Details

Type

Article

Created At

23 Dec 2024