Beta
349174

In-Vitro Evaluation of Strain Induced by Various Extra Coronal Attachment Materials in Removable Partial Dentures Restoring Mandibular Kennedy Class I Following Clinical Simulati

Article

Last updated: 23 Dec 2024

Subjects

-

Tags

Removable Prosthodontics

Abstract

ABSTRACT
Purpose: The objective of this study was to evaluate the strain induced by various extra coronal attachment materials retaining removable partial dentures restoring mandibular Kennedy class I following clinical simulation for one year.
Materials and Methods: Twelve identical models, fabricated by 3D printing, representing Kennedy class I mandibular partially edentulous cases with bilateral first premolars as primary abutments were used. Each model had four removable dies; canines and first premolars bilaterally. On these dies, bilateral splinted crowns were fabricated and grouped according to the extra coronal attachment material used (PEEK/BioHPP, zirconia and metal). Each group included four model, each model was designed having four slots for strain gauges (two on each side). These slots were positioned 1mm distal to the 1st premolar (SG1 and SG3) and at the edentulous ridge (SG2 and SG4) 1 cm away from the first one. Removable partial dentures were fabricated, and a universal testing machine was employed to assess the strain induced under unilateral and bilateral loading conditions. This assessment was conducted both prior to and after clinical simulation for one year. The clinical simulation involved chewing simulator sessions and cycles of insertion and removal for the denture.
Results: PEEK (BioHPP) group exhibited the least strain induced, both prior to and after clinical simulation for one year, under both unilateral and bilateral loading conditions.
Conclusions: PEEK (BioHPP) extra coronal attachment used for retaining removable partial denture provides more favorable stress dissipation in comparison to zirconia and metal attachments.
KEYWORDS:
PEEK, zirconia, metal, strain gauges

DOI

10.21608/edj.2024.269202.2935

Keywords

PEEK, Zirconia, metal, strain gauges

Authors

First Name

Yasser

Last Name

Shawky

MiddleName

Mohamad

Affiliation

Associate Professor of Prosthodontics, Faculty of Oral and Dental Medicine, Misr International University MIU

Email

yasser.shawky@miuegypt.edu.eg

City

Cairo

Orcid

0000-0003-3089-9398

Volume

70

Article Issue

2

Related Issue

47036

Issue Date

2024-04-01

Receive Date

2024-02-24

Publish Date

2024-04-01

Page Start

1,771

Page End

1,790

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_349174.html

Detail API

https://edj.journals.ekb.eg/service?article_code=349174

Order

349,174

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

In-Vitro Evaluation of Strain Induced by Various Extra Coronal Attachment Materials in Removable Partial Dentures Restoring Mandibular Kennedy Class I Following Clinical Simulation for One Year

Details

Type

Article

Created At

23 Dec 2024