Beta
349162

Retention And Functionality Assessment for Two Design of Interim Maxillary Obturator

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

Removable Prosthodontics

Abstract

Objectives: Maxillary obturator wearers suffer from improper retention and function of maxillary obturator. The aim of the study is to evaluate the conventional design of interim obturator utilizing multiple wrought wore clasps versus extended hinged-buccal-flange utilizes soft and dental tissue for retention.
Materials and Methods: fifteen participants with maxillary palatal defect were included in this crossover clinical study based on inclusion criteria. Each participant received conventional interim obturator with multiple wrought wire clasps (Design I); and was replaced with interim obturator retained by hinged-buccal flange extended form the sulcus full depth to the engage the labial and buccal undercuts of remaining teeth in the intact side. (Design II). The retention was evaluated at insertion (T1), after 30 days (T2) and after two months of insertion (T3). The oral function was evaluated by obturator functioning scale (OFS).
Result: At comparing the reported difficulties with obturator designs at different function, there was a significant difference for items 11, 13, 14, 15 (p =0.001, 0.09, <0.01 and 0.19 respectively). For retention evaluation, there was a significant reduction in retention with each group based on obturator design (p< 0.001). At comparing retention of both designs, there was significant increase of design II at the terminal of the study.
Conclusion: Within the limitation of the study, utilizing soft and dental undercuts by hinged-buccal flange design enhances retention, esthetic feedback and manipulation of the interim maxillary obturator comparing to the conventional multiple wrought wire clasps design.

DOI

10.21608/edj.2024.263214.2884

Keywords

obturator, wearers, multiple wrought wire clasps, hinged-buccal flange

Authors

First Name

Mohamed

Last Name

Denewar

MiddleName

-

Affiliation

Department of Prosthodontics, Faculty of Oral and Dental Medicine, Delta University for Science and Technology, Dakahlia, Egypt

Email

drdenewar@gmail.com

City

-

Orcid

0000-0002-8192-818X

First Name

Ahmed

Last Name

Khalifa

MiddleName

-

Affiliation

Department of Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura, Egypt 2 Department of Prosthodontics technologies, Faculty of Applied Health Science Technology, New Mansoura University, Egypt

Email

a_khalifa@mans.edu.eg

City

Mansoura

Orcid

0000-0003-3360-628X

Volume

70

Article Issue

2

Related Issue

47036

Issue Date

2024-04-01

Receive Date

2024-01-21

Publish Date

2024-04-01

Page Start

1,651

Page End

1,659

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_349162.html

Detail API

https://edj.journals.ekb.eg/service?article_code=349162

Order

349,162

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Retention And Functionality Assessment for Two Design of Interim Maxillary Obturator

Details

Type

Article

Created At

23 Dec 2024