Beta
349154

Effect of layer thickness, inner structure, and implant angulation on the accuracy of 3D printed models with implant analogs

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

Fixed Prosthodontics

Abstract

Objective: This study evaluated the effect of layer thickness, model inner structure, and implant
angulation on the accuracy of 3D printed models with repositional analogs. Materials and
methods: 126 models designed to receive all-on-4 implant retained fixed dental prosthesis
were 3D printed. Models were divided into 2 groups (n=63) according to posterior implant
angulation (Group 1; 30 ᵒ and group 2;45 ᵒ). The models were then divided into three subgroups
(n=21) according to the printing layer thickness (Group a; 50 µm, group b; 100 µm, and group c;
150 µm). Each subgroup was later subdivided into 3 divisions (n=7) according to the model
inner structure (Group I; solid, group II; hollow, and group III; honeycomb). Trueness was
analyzed using Geomagic controlX analysis software by comparing the model scans to the
reference model STL file. Results: Both inner structure and layer thickness had a significant
effect on the final accuracy. Implant angulation had no effect on the final
accuracy of the printed model. Regarding layer thickness, tukeys post-hoc test
revealed that both 100 µm (24.9± 2.4) and 150 µm (24.5 ± 1.1) layer thickness showed higher
accuracy than the 50 µm (27.9 ± 2.4). As for model form, tukeys post hoc test
revealed that the solid (24.9 ± 1.4) and honeycomb (25 ± 1.5) models were more accurate than
the hollow models (27.5±3.3). Conclusion: Implant angulation had no effect on the final
accuracy of the model. Both 50 µm print layer thickness and hollow model inner structure
showed the least accuracy.

DOI

10.21608/edj.2024.260280.2860

Keywords

Implant scan body, digital dentistry, digital impressions, implant analogs, Digital Analogs

Authors

First Name

Ingy

Last Name

Nouh

MiddleName

-

Affiliation

Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.

Email

ingynouh@asfd.asu.edu.eg

City

-

Orcid

0000-0002-9079-0151

First Name

Nancy

Last Name

Rafla

MiddleName

-

Affiliation

Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.

Email

nancyessam@dent.asu.edu.eg

City

-

Orcid

0000-0001-7614-2871

First Name

Omar

Last Name

El Sergany

MiddleName

Ahmed

Affiliation

Department of Fixed Prosthodontics, Faculty of Dentistry, British University in Egypt, Cairo, Egypt.

Email

omar.elsergany@bue.edu.eg

City

-

Orcid

0009-0003-2043-9467

Volume

70

Article Issue

2

Related Issue

47036

Issue Date

2024-04-01

Receive Date

2024-01-03

Publish Date

2024-04-01

Page Start

1,567

Page End

1,575

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_349154.html

Detail API

https://edj.journals.ekb.eg/service?article_code=349154

Order

349,154

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Effect of layer thickness, inner structure, and implant angulation on the accuracy of 3D printed models with implant analogs

Details

Type

Article

Created At

23 Dec 2024