Abstract

Background: New types of CAD/CAM materials are currently used on wide scales to reinforce implant-retained overdentures as a substitute for conventionally non-reinforced overdentures; thus, further studies are needed to validate these materials.
Methodology: Fifteen implant-retained overdentures were constructed. Three completely edentulous 3D-printed models were obtained, in which 6 laboratory implant analogs were secured in the position of teeth 33 and 43 with ball attachment. The 3D-printed models were divided into 3 groups. Group 1 received five mandibular implant retained overdentures reinforced with poly-ether-ketone-ketone (PEKK) meshwork. Group 2 received mandibular implant-retained overdentures reinforced with fiberglass-reinforced composite resin (FRC) meshwork. Group 3 received five mandibular implants retained overdenture reinforced with cobalt chromium (CoCr) meshwork. A universal testing machine was used to evaluate the fracture resistance of the fifteen overdentures, and the recorded data were collected, tabulated, and statistically analyzed.
Results: There was a significant difference between group 3 and groups 1 and 2, while there was no significant difference between groups 1 and 2. The greatest fracture load was found in Group 1 (4310 ± 214.57), followed by Group 2 (4261 ± 218.41), and the lowest fracture load was found in Group 3 (3877 ± 201.74).
Conclusion: The (FRC) and (PEKK) meshworks provided better alternatives to CoCr. meshwork as a reinforcement material in heat-cured acrylic resin implant retained overdentures.

DOI

10.21608/edj.2023.235049.2712

Keywords

Keywords: Denture fracture, Poly ether ketone ketone, Cobalt Chromium, fiber-reinforced composite resins

Authors

First Name

May

Last Name

Hassan

MiddleName

Mahmoud

Affiliation

Lecturer, Removable Prosthodontic Department, College of Oral and Dental Surgery, Misr University for Science and Technology, Giza, Egypt

Email

beauty_girl8310@hotmail.com

City

-

Orcid

0000-0002-9144-5392

First Name

Heba

Last Name

Elsarrif

MiddleName

Refaat

Affiliation

Lecturer, Removable Prosthodontic Department, College of Oral and Dental Surgery, Misr University for Science and Technology, Giza, Egypt

Email

heba.elsarif@must.edu.eg

City

cairo

Orcid

0000-0002-6963-1586

Volume

70

Article Issue

1

Related Issue

45237

Issue Date

2024-01-01

Receive Date

2023-09-08

Publish Date

2024-01-01

Page Start

377

Page End

385

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_334106.html

Detail API

https://edj.journals.ekb.eg/service?article_code=334106

Order

334,106

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

A Comparative Study of Different CAD/CAM Materials Reinforcing Implant Retained Overdenture Base Material (An In vitro Study)

Details

Type

Article

Created At

23 Dec 2024