334103

Accuracy of Intraoral Scanning of Implant Level Impression Technique Versus Abutment Level Impression In Implant Mandibular Supported Overdenture. In-Vitro Study

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

Removable Prosthodontics

Abstract

Intraoral scanning has recently been investigated showing high accuracy in complete implant supported cases. The aim of this in vitro study was to compare the accuracy of intraoral scanning techniques for implant level impression versus abutment level impression techniques in patients with mandibular supported overdenture. Methods: Ready-made scannable foam cast of completely edentulous mandible was scanned using the extraoral scanner representing an edentulous mandible where four implant were placed. This cast was used as the control group; which was used to fabricate one cast with the implant level impression technique and the other to fabricate cast with abutment level impression technique as interventions. For both interventions; Digital intraoral scans (DIOS) were made after connecting implant level scan bodies to the master cast and STL files were exported to be used in the superimposition by a MEDIT COMPARE software for determining the accuracy of both techniques.
Results: There was a statistically significant difference between (Implant level) and (Abutment level) where (p=0.008). Conclusion: The implant level impression technique is more accurate than the abutment level impression technique when using Digital intraoral scanning.

DOI

10.21608/edj.2023.233018.2697

Keywords

Dimensional Measurement Accuracies, Implant-Supported Dental Prosthesis, Dental Impression Technic, Digital technologies

Authors

First Name

Doaa

Last Name

Elkady

MiddleName

Mahmoud

Affiliation

Lecturer of Prosthodontic Department, Faculty of Dentistry, Cairo University

Email

doaa.elkady@dentistry.cu.edu.eg

City

ElObour

Orcid

0000-0003-4892-9145

First Name

Nesma

Last Name

Awaad

MiddleName

-

Affiliation

Lecturer of Prosthodontic Department, Faculty of Dentistry, Cairo University

Email

nesmaawaad@dentistry.cu.edu.eg

City

Cairo

Orcid

0000-0001-6720-4567

Volume

70

Article Issue

1

Related Issue

45237

Issue Date

2024-01-01

Receive Date

2023-08-30

Publish Date

2024-01-01

Page Start

353

Page End

361

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_334103.html

Detail API

https://edj.journals.ekb.eg/service?article_code=334103

Order

334,103

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Accuracy of Intraoral Scanning of Implant Level Impression Technique Versus Abutment Level Impression In Implant Mandibular Supported Overdenture. In-Vitro Study

Details

Type

Article

Created At

23 Dec 2024