Beta
332257

Invitro Evaluation of Forces Delivered by Aligners Fabricated using Positive Air Pressure versus Negative Air Pressure.

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

Orthodontics

Abstract

Objective: To measure the difference in force delivery between aligners fabricated using positive air pressure versus negative air pressure.

Material and methods: A series of clear aligners of similar material composition (PET-G), manufacturer (Scheu Dental), thickness (0.75mm) and activation of 0.2mm uncontrolled palatal tipping on the upper left central incisor were designed and fabricated using two different methods of fabrication. The first set of aligners (n=5) were fabricated via positive air pressure using MiniStarS pressure thermoforming and the second set (n=5) were fabricated via negative air pressure using the PlastVac P7 vacuum forming machine. A force change measurement system was used to measure changes in the forces delivered by the pressure formed and vacuum formed PET-G materials. Statistical analysis was carried independent samples t test to compare between pressure formed and vacuum formed force values using Significance level was considered at P < 0.05.

Results: There was a statistically significant increase in force values delivered by aligners thermoformed using positive air pressure compared to aligners fabricated using negative air pressure. Forces delivered by vacuum formed aligners averaged to 0.40N compared with 1.01N for aligners thermoformed using positive air pressure.

Conclusions: The forces delivered by aligners are influenced by the fabrication process; aligners fabricated using positive pressure showed increased fit and adaptation on the resin model which led to an increase in the delivered forces compared to aligners fabricated using negative pressure.

DOI

10.21608/edj.2023.248370.2780

Keywords

aligners, Force, Positive air pressure

Authors

First Name

Nada

Last Name

Hamed

MiddleName

-

Affiliation

Instructor, Orthodontic Department, Faculty of Dentistry, Ain Shams University, Cairo-Egypt

Email

nadahamed@asfd.asu.edu.eg

City

Cairo

Orcid

0000-0002-4850-0819

First Name

Islam

Last Name

Hassan

MiddleName

Tarek

Affiliation

Professor and Head of Department, Orthodontic Department, Faculty of Dentistry, Ain Shams University, Cairo, Egypt

Email

itarek@gmail.com

City

-

Orcid

0000-0001-9893-2057

First Name

Dina

Last Name

Elghoul

MiddleName

Hussein

Affiliation

Professor, Orthodontic Department, Faculty of Dentistry, Ain Shams University, Cairo, Egypt

Email

dinaelghoul@gmail.com

City

Cairo

Orcid

0000-0003-2422-0852

First Name

Eman

Last Name

Elabbassy

MiddleName

Hossameldin

Affiliation

Associate Professor, Orthodontic Department, Faculty of Dentistry, Ain Shams University, Cairo, Egypt

Email

emanhossamelabbassy@gmail.com

City

Cairo

Orcid

0000-0003-0591-9676

First Name

Ahmed

Last Name

Zaky

MiddleName

-

Affiliation

Lecturer, Orthodontic Department, Faculty of Dentistry, Ain Shams University, Cairo, Egypt

Email

drahmedzaky@gmail.com

City

-

Orcid

0000-0002-7510-7051

Volume

70

Article Issue

1

Related Issue

44981

Issue Date

2024-01-01

Receive Date

2023-11-15

Publish Date

2024-01-01

Page Start

53

Page End

58

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_332257.html

Detail API

https://edj.journals.ekb.eg/service?article_code=332257

Order

332,257

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Invitro Evaluation of Forces Delivered by Aligners Fabricated using Positive Air Pressure versus Negative Air Pressure.

Details

Type

Article

Created At

23 Dec 2024