Beta
320075

Comparing the retention of the ball attachment retained mini-implant mandibular over denture using different retentive mechanisms. A Randomized Clinical Trial

Article

Last updated: 23 Dec 2024

Subjects

-

Tags

Removable Prosthodontics

Abstract

The purpose of this study was to compare the retention of different three retention mechanisms (metal housing with nylon cap, PEEK and retention sil) in ball attachment retained mini-implant mandibular over denture.

Methodology: A total of fifteen completely edentulous male patients were selected from outpatient clinic of the prosthodontics department. the patients were then randomly divided into three groups as six patients per group. Group I: overdentures retained by
with conventional metal housing and nylon caps, Group II: overdentures retained by
with silicone housing retention sil, Group III: overdentures retained by
with PEEK housing.
All patients were scheduled for retention evaluation in a regular follow up visits at time of insertion, 3 months and 6months.
Results:
The results revealed there was a statistical significance increase in retention values in Group III : overdentures retained with PEEK housing when compared to Group I and Group II and the least retention values were recorded in Group II: overdentures retained with silicone housing retention sil at throughout the whole follow up period, While the comparison between different intervals revealed insignificant difference in all groups as P>0.05 (retention insignificantly decreased in all groups) at all intervals.

DOI

10.21608/edj.2023.216514.2588

Keywords

Mini -implants, PEEK housing, Metal housing and Nylon caps, overdenture

Authors

First Name

mai

Last Name

helmy

MiddleName

adel

Affiliation

Associate Professor of Prosthodontics Cairo University

Email

mai.helmy@dentistry.cu.edu.eg

City

cairo

Orcid

0000-0002-8417-4408

First Name

Noha

Last Name

Gamaleldin

MiddleName

Ali

Affiliation

Associate Professor of Prosthodontics Cairo University

Email

noha.agamaleldin@dentistry.cu.edu.eg

City

cairo

Orcid

0000-0002-0155-8896

Volume

69

Article Issue

4

Related Issue

43786

Issue Date

2023-10-01

Receive Date

2023-06-09

Publish Date

2023-10-01

Page Start

2,837

Page End

2,846

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_320075.html

Detail API

https://edj.journals.ekb.eg/service?article_code=320075

Order

320,075

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Comparing the retention of the ball attachment retained mini-implant mandibular over denture using different retentive mechanisms. A Randomized Clinical Trial

Details

Type

Article

Created At

23 Dec 2024