Beta
305748

Marginal fit and fracture resistance of advanced lithium disilicate occlusal veneer with different preparation designs

Article

Last updated: 23 Dec 2024

Subjects

-

Tags

Fixed Prosthodontics

Abstract

Aim: This study aimed to evaluate the effect of different preparation designs of advanced lithium disilicate (CEREC Tessera) occlusal veneer on marginal fit and fracture resistance.
Materials and methods: Twenty extracted mandibular molar teeth were used for occlusal veneers fabrication. Division of samples was carried out by the preparation design into two groups (n=10). group 1: The teeth were prepared with 900 shoulder finish line. group 2: The chamfer finish line was the technique of choice in teeth preparation. Both groups were subjected to thermocycling. The stereomicroscope was used to examine all samples for marginal fit before being subjected to the test of fracture resistance utilizing the universal testing machine.
Results: Marginal fit results showed that the shoulder finish line design had a significantly lower mean value (75.8±6.4 μm) than that using the chamfer finish line design mean value (128.1±12.6 μm). The fracture resistance results demonstrated that the shoulder design had a higher significant mean value (870.2±72.5 N) than that using the chamfer design (711.2±66.6 N).
Conclusions : Advanced lithium disilicate (CEREC Tessera) could be used in occlusal veneer restoration as their flexural strength and marginal fit values fall within the clinically accepted range. Regarding the preparation design, the shoulder design showed more resistance to fracture and better marginal fit than the chamfer finish line design after thermocycling.

DOI

10.21608/edj.2023.204093.2507

Keywords

Fracture resistance, Marginal fit, Lithium Disilicate, Occlusal veneer

Authors

First Name

Raiesa

Last Name

Hashem

MiddleName

Mohamed

Affiliation

Fixed prosthodontics department, faculty of dentistry,minia university, Egypt

Email

samahhashem34@mu.edu.eg

City

Minia

Orcid

0000-0002-3034-2883

Volume

69

Article Issue

3

Related Issue

42136

Issue Date

2023-07-01

Receive Date

2023-04-04

Publish Date

2023-07-01

Page Start

2,115

Page End

2,125

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_305748.html

Detail API

https://edj.journals.ekb.eg/service?article_code=305748

Order

305,748

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Marginal fit and fracture resistance of advanced lithium disilicate occlusal veneer with different preparation designs

Details

Type

Article

Created At

23 Dec 2024