Abstract

Objectives: To evaluate the effect of two thermal tempering cycles on marginal accuracy of crowns fabricated from two heat-pressed glass ceramics.
Materials and methods: Twenty-eight ceramic crowns were pressed from glass ceramic materials in two groups (n=14). Group (E): Lithium disilicate IPS e.max Press, Group (C): Zirconia reinforced lithium silicate (ZLS) Celtra Press. Each group was subdivided according to tempering temperature into (T1) 9% and (T2) 5% below pressing temperature of each ceramic. A stereomicroscope was used to measure the marginal adaptation before and after tempering and microstructure was analyzed. Three-way ANOVA test was used to study the effect of ceramic type, tempering, tempering procedure and their interactions on marginal gap distance. Bonferroni's post-hoc test was used for pair-wise comparisons when ANOVA test is significant. The significance level was set at P ≤ 0.05.
Results: The interaction between the three variables had statistically significant effect on mean marginal gap distance (P-value <0.001). Before tempering and after (T1) tempering, there was no statistically significant difference between ceramic types (P-value = 0.577). After (T2) tempering, there was a statistically significant difference between ceramic types (P-value <0.001). Celtra showed statistically significantly higher mean marginal gap distance compared to E.max.
Conclusions: Mean marginal gap distance for lithium disilicate was not affected after tempering. ZLS after -5% tempering showed the highest mean marginal gap distance. All tested groups showed clinically acceptable marginal adaptation except ZLS with -5% tempering which showed clinically unacceptable marginal adaptation >120 µm.

DOI

10.21608/edj.2023.187867.2412

Keywords

Lithium Disilicate, zirconia lithium silicate, Thermal tempering, marginal adaptation, Microstructural analysis

Authors

First Name

Mohammad

Last Name

abdelkhader

MiddleName

-

Affiliation

Master's degree student, Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.

Email

mohwajeeh@hotmail.com

City

-

Orcid

0000-0002-2215-8453

First Name

Amr

Last Name

El-Etreby

MiddleName

-

Affiliation

Professor, Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.

Email

prof.amreletreby@gmail.com

City

cairo

Orcid

0000-0003-3731-3847

First Name

Marwa

Last Name

Emam

MiddleName

-

Affiliation

Lecturer, Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt. , Visiting researcher, Oral Technology, Rheinische Friedrich-Wilhelms University, Hospital Bonn, Germany.

Email

marwaemam@asfd.asu.edu.eg

City

cairo

Orcid

0000-0003-0856-0689

Volume

69

Article Issue

3

Related Issue

42136

Issue Date

2023-07-01

Receive Date

2023-01-19

Publish Date

2023-07-01

Page Start

2,083

Page End

2,091

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_305745.html

Detail API

https://edj.journals.ekb.eg/service?article_code=305745

Order

305,745

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Evaluation of Marginal Accuracy and Microstructure of Heat Pressed Lithium Disilicate and Zirconia Reinforced Lithium Silicate Crowns after Thermal Tempering

Details

Type

Article

Created At

23 Dec 2024