294221

Assessment of the Correlation between Implant Diameters and Cantilever Lengths to Anterior-Posterior Spread ratio utilizing Resonance Frequency Analysis (Implant Stability Quotie

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

Removable Prosthodontics

Abstract

Objectives: This study aims to assess the correlation between different implant diameters and different cantilever lengths to anterior-posterior spread on the stability of implants placed in maxillary edentulous ridges.
Materials and methods: In sixteen patients, a total of 96 implants were implanted, over which screw-retained implant-supported maxillary prostheses were constructed. The patients were divided into two groups using sealed envelopes for randomization: Group I received implants with a small diameter of 3.0 mm, while Group II received implants with a standard diameter of 3.7 mm. Patients in each group were further divided into two subgroups, Groups IA, IB, and Groups IIA, and IIB. The cantilevers lengths to anterior-posterior AP implant spread (CL: AP) in Groups IA and IIA was at a ratio of 1:3, whereas in Groups IB and IIB, the CL: AP was performed at a ratio of 1:2. Implant Stability Values were measured at 0, 4, 8, and 24 months after prostheses delivery.
Results: The correlation between Implant Stability ISQ values and different implant diameters was calculated by using Spearman`s correlation coefficient which revealed a positive (+), weak (r=0.21), insignificant (P=0.16) correlation, while the Correlation between Implant Stability ISQ values and different cantilever lengths were calculated by using Spearman`s correlation coefficient which revealed a negative (-), weak (r=-0.529), significant (P<0.0001*) correlation.
Conclusion: Within the limitations of this study, it can be concluded that changing the AP spread to cantilever lengths and varying implant diameter may have an impact on the stability of implants supporting maxillary screw-retained prostheses

DOI

10.21608/edj.2023.183701.2388

Keywords

edentulous maxillae, small diameter implants, screw retained, Cantilever

Authors

First Name

Heba

Last Name

Khorshid

MiddleName

-

Affiliation

A. Professor of Prosthodontics, Faculty of Oral & Dental Medicine, Cairo University

Email

hebakhorshid@hotmail.com

City

-

Orcid

0000-0002-4416-9305

First Name

MOSTAFA

Last Name

MOSTAFA AHMED

MiddleName

-

Affiliation

A. Professor of Prosthodontics, Faculty of Oral & Dental Medicine, Cairo University)

Email

mostafa.helmy@dentistry.cu.edu.eg

City

CAIRO

Orcid

0000-0002-5701-4070

Volume

69

Article Issue

2

Related Issue

40704

Issue Date

2023-04-01

Receive Date

2022-12-27

Publish Date

2023-04-01

Page Start

1,241

Page End

1,249

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_294221.html

Detail API

https://edj.journals.ekb.eg/service?article_code=294221

Order

7

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Assessment of the Correlation between Implant Diameters and Cantilever Lengths to Anterior-Posterior Spread ratio utilizing Resonance Frequency Analysis (Implant Stability Quotie

Details

Type

Article

Created At

23 Dec 2024