Abstract

Aim of the study: The objective was to asses and compares the effect of PEEK and Zirconia primary copings in milled double crown PEEK framework. Materials and methods: One cast was fabricated simulating Kennedy Class I with the premolars as the last standing abutment. The primary copings were classified into two groups, milled PEEK group I and milled Zirconia group II. Two milled PEEK frameworks were used. Four strain gauges were installed bilaterally in the model. A load of 100 N was applied to the area of the first molar bilaterally. The same procedure was repeated 10 times. Cyclic loading was applied simulating 1 year of function. Strains induced on the abutments during bilateral loading were evaluated before and after chewing simulation. Results: The highest compressive micro-strain was recorded at channel (4) after cyclic loading for PEEK group 359.00±5.055 µm/m followed by channel (2) 356±13.293 µm/m. While the least compressive micro-strain was recorded at channel (1) before cyclic loading for the Zirconia was 150±7.817 µm/m. There was significant difference in channels (2) and (4) regarding PEEK group before and after cyclic loading. While for Zirconia group there was significance difference in channels (1) and (3) before and after cyclic loading where P value was

DOI

10.21608/edj.2023.172395.2334

Keywords

PEEK, Double Crown, Strain gauge, Partial Denture, Chewing simulation

Authors

First Name

Mahmoud

Last Name

Homossany

MiddleName

-

Affiliation

Associate Professor, Removable Prosthodontics Department. Ain Shams University, Cairo, Egypt

Email

r_homosany@hotmail.com

City

-

Orcid

0000-0002-1790-4626

First Name

Hebatallah

Last Name

Mohamed

MiddleName

-

Affiliation

Associate Professor, Removable Prosthodontics Department. Ain Shams University, Cairo, Egypt

Email

hebatullah.tarek@dent.asu.edu.eg

City

cairo

Orcid

0000000282804656

Volume

69

Article Issue

1

Related Issue

39262

Issue Date

2023-01-01

Receive Date

2022-11-02

Publish Date

2023-01-01

Page Start

639

Page End

651

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_283281.html

Detail API

https://edj.journals.ekb.eg/service?article_code=283281

Order

20

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Comparative Stress Analysis Study Of CAD/CAM Milled PEEK And Zirconia Primary Copings In Double Crown PEEK Framework Mandibular Partial Denture After 1 Year Simulated Function

Details

Type

Article

Created At

23 Dec 2024