Beta
388492

Monitoring of plethysmography variability index and total hemoglobin levels during cesarean sections with antepartum hemorrhage for early detection of bleeding

Article

Last updated: 31 Dec 2024

Subjects

-

Tags

-

Abstract

Background
Cesarean sections for parturients with antepartum hemorrhage have the potential risk of massive blood loss. In the current study we investigated the use of Plethysmography variability index (PVI) and non invasive hemoglobin (SPHB) monitoring as well for intraoperative detection of blood loss and intravascular volume status.
Methods
One hundred and twenty four full term parturients scheduled for elective CS were included in the study. All patients received general anesthesia after preoxygenation for 5 min, rapid-sequence induction performed with thiopental 3–5 mg/kg and suxamethonium 1.5 mg/kg; Anesthesia was maintained with a 100% of oxygen with 0.5–1 MAC of isoflurane and atracurium 0.5 mg/kg. Standard monitors (pulse oximetry, non-invasive blood pressure, and ECG) were applied. Masimo sensor was applied following best practice guidelines, and automated data collection (ADC) was done. Our primary outcome was to compare PVI values before versus after administration of fluids and blood that was given based on clinical data. Our secondary outcome was to review of SPHb traces plots to determine if and when SPHb may have detected presence of anemic state or critical drop in hemoglobin level when compared to time of clinical awareness of bleeding and confirmation by lab Hb sample measurement.
Results
PVI showed a significant negative correlation with CVP (p = 0.037) and a significant negative correlation with MAP (p = 0.01). Also, it showed significant positive correlation with HR (p < 0.001). A highly significant Correlation was found between pre transfusion lab Hb and pre transfusion SpHb (p < 0.001). Also post transfusion values showed a highly significant correlation as well (p < 0.001). A total of 87 transfusions (91.58%) were found unnecessary when using SpHb as the reference, compared to 58 (61.05%) when using the invasive laboratory measurement.
Conclusion
Plethysmography variability index and non invasive hemoglobin monitoring as well can be used for optimization of intravascular volume status during cesarean sections in parturients with antepartum hemorrhage.

DOI

10.1016/j.egja.2016.10.007

Authors

First Name

Ahmed

Last Name

Elsakka

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Wael

Last Name

Hossam

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Gehan

Last Name

Helmy

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Nadia

Last Name

Helmy

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

Volume

33

Article Issue

1

Related Issue

51199

Issue Date

2017-01-01

Receive Date

2016-06-06

Publish Date

2017-01-01

Page Start

5

Page End

8

Print ISSN

1110-1849

Online ISSN

1687-1804

Link

https://egja.journals.ekb.eg/article_388492.html

Detail API

https://egja.journals.ekb.eg/service?article_code=388492

Order

388,492

Publication Type

Journal

Publication Title

Egyptian Journal of Anaesthesia

Publication Link

https://egja.journals.ekb.eg/

MainTitle

Monitoring of plethysmography variability index and total hemoglobin levels during cesarean sections with antepartum hemorrhage for early detection of bleeding

Details

Type

Article

Created At

21 Dec 2024