Beta
388423

Comparing transesophageal Doppler corrected systolic flow time versus central venous pressure as a guide for fluid resuscitation in septic shock

Article

Last updated: 21 Dec 2024

Subjects

-

Tags

-

Abstract

Background
Aortic corrected flow time (FTc) is easily measured by Doppler techniques. Recent data using transesophageal Doppler suggest that it may predict fluid responsiveness in critical care. This use of FTc has not previously been evaluated in septic shock, and only one preliminary study has incorporated transcutaneously measured FTc, denoting its importance in prediction of fluid responsiveness in septic patient. Furthermore, no comparison has been made between transesophageal FTc and central venous pressure (CVP).
Objective
The aim of our study was to compare the impact of using FTc versus CVP as a guide for fluid resuscitation in septic shock on stroke volume denoting cardiac responsiveness for fluid administration.
Methods
This was a prospective study of 46 consecutive adult septic shock patients (in sinus rhythm). 44 patients were mechanically ventilated, treated with intravenous fluid challenge (500 mL over 15 min), guided with CVP in control group and guided by FTC in Doppler group assessment incorporating transesophageal aortic Doppler (CardioQ®) measurements in a surgical tertiary intensive care unit. Stroke volume (SV), mechanical ventilation days, length of stay and mortality of both groups were recorded.
Results
Fourty one patients demonstrated an increase in stroke volume (SV) by more than 10% (fluid responders) while five patients were non responders. There were statistically significant increases in SV after 1 h post resuscitation in the Doppler group as the values were 63.87 ± 25.87 & 81.39 ± 35.02 in the control group and the Doppler group respectively ( value = 0.034). There were statistically significant differences in FTc values after 1 h [397.00 (390.00–404.00) & 362.00 (351.00–377.00)] between non-responders and responders respectively ( value was 0.003) and after 6 h [377.00 (376.00–378.00) & 330.00 (314.00–353.00)] between non-responders and responders respectively ( value was 0.007).
Conclusion
Transesophageal aortic Doppler is a simple, non-invasive tool of guiding fluid therapy in patients with severe sepsis and septic shock. FTC change was a better predictor of fluid responsiveness than CVP in septic shock. There was higher significant difference in SV after resuscitation when using FTC as guidance.

DOI

10.1016/j.egja.2015.12.004

Authors

First Name

Walid

Last Name

Hamimy

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Ahmed

Last Name

Mukhtar

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Ahmed

Last Name

Zaghloul

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Mahmoud

Last Name

Salem

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

Volume

32

Article Issue

2

Related Issue

51195

Issue Date

2016-04-01

Receive Date

2015-12-07

Publish Date

2016-04-01

Page Start

181

Page End

187

Print ISSN

1110-1849

Online ISSN

1687-1804

Link

https://egja.journals.ekb.eg/article_388423.html

Detail API

https://egja.journals.ekb.eg/service?article_code=388423

Order

388,423

Publication Type

Journal

Publication Title

Egyptian Journal of Anaesthesia

Publication Link

https://egja.journals.ekb.eg/

MainTitle

Comparing transesophageal Doppler corrected systolic flow time versus central venous pressure as a guide for fluid resuscitation in septic shock

Details

Type

Article

Created At

21 Dec 2024