Beta
388077

Sequential higher epidural catheter re-insertion after accidental dural puncture ameliorates the frequency and severity of post-dural puncture headache

Article

Last updated: 31 Dec 2024

Subjects

-

Tags

-

Abstract

Objectives
This cohort study aimed to evaluate the outcome of a hypothesis to use higher level for epidural catheter insertion and activation when an epidural tap was encountered at a lower level during epidural analgesia for labor pain.
Methods
Epidural analgesia for labor pain was conducted using a mixture of 0.125% bupivacaine and fentanyl 5 μg/ml (10–15 ml) in 5-ml increments and maintained using continuous epidural infusion of 0.125% bupivacaine and fentanyl 2 μg/ml at rate of (5–15 ml/h), subsequently adjusted according to the patients needs. All cases had accidental dural puncture ADP) were managed immediately with re-insertion of the needle at a higher level and completion of the procedure and maintained using continuous epidural infusion of 0.0625% bupivacaine and fentanyl 2 μg/ml at rate of (6–12 ml/h) for 24 h after delivery. Postpartum follow-up was conducted for 30 days to comment on the occurrence and severity of post-dural puncture headache (PDPH). All patients developed PDPH were followed daily until resolution of their headache.
Results
About 4800 parturient were enrolled in the study, ADP occurred in 24 patients with a frequency of 0.5%. All cases were immediately managed by re-insertion of the needle at a higher level and the procedure was successfully completed without new dural puncture, with 100% re-insertion success rate, and patients were maintained on continuous epidural infusion for 24 h. Throughout 30-day follow-up; only six of 24 patients developed PDPH with a success rate of re-insertion procedure as a prophylactic modality for PDPH after ADP of 75%. PDPH was relieved with bed rest, liberal fluids and paracetamol for 4 days in four patients, while the 5th patient continued to complain but the patient refused to undergo epidural blood patch (EBP) and headache started to subside and patient stopped to complain by the 10th day, and the last patient agreed to undergo EBP; and headache was relived immediately after 2 h.
Conclusion
It could be concluded that re-insertion of epidural catheter at higher level of accidental dural puncture with epidural continuous infusion for 24 h could be considered as an efficient prophylactic modality to safe guard against PDPH with success rate of 75% and minimizes its severity if occurred.

DOI

10.1016/j.egja.2010.04.001

Keywords

epidural, Post-Dural Puncture Headache, Labor Pain

Authors

First Name

Somaya

Last Name

ElSheikh

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Ghada

Last Name

Gamal

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

Volume

26

Article Issue

4

Related Issue

51167

Issue Date

2010-10-01

Receive Date

2010-03-18

Publish Date

2010-10-01

Page Start

261

Page End

265

Print ISSN

1110-1849

Online ISSN

1687-1804

Link

https://egja.journals.ekb.eg/article_388077.html

Detail API

https://egja.journals.ekb.eg/service?article_code=388077

Order

388,077

Publication Type

Journal

Publication Title

Egyptian Journal of Anaesthesia

Publication Link

https://egja.journals.ekb.eg/

MainTitle

Sequential higher epidural catheter re-insertion after accidental dural puncture ameliorates the frequency and severity of post-dural puncture headache

Details

Type

Article

Created At

21 Dec 2024