Beta
387949

Impact of pre-spinal atropine on post spinal hemodynamic and cardiac output measured by electrical cardiometry in cesarean delivery, a randomized controlled trial

Article

Last updated: 31 Dec 2024

Subjects

-

Tags

-

Abstract

Background
Spinal anesthesia is a widely used technique for cesarean delivery, but it often results in hypotension, bradycardia, and reduced cardiac output (CO). Atropine has a potent muscarinic receptor antagonist activity in the heart. It may be a good choice to prevent post-spinal bradycardia and minimize the marked CO reduction.
Methods
Sixty pregnant women between the ages of 18 and 40 who were ASA-PS II and planned for elective cesarean delivery were divided into two equal groups at random. Both groups received spinal anesthesia. Atropine group (I) ( = 30): patients received 0.01 mg/kg atropine, while control group (II) ( = 30): patients received the same volume of saline. CO measured by electrical cardiometry (EC) was the primary outcome where, heart rate (HR), mean blood pressure (MBP), stroke volume (SV), systemic vascular resistance (SVR), and neonatal outcomes were the secondary outcomes.
Results
CO after the intervention was higher in the atropine (group I) than in the control (group II). Also, CO reduction at 5 and 10 min following spinal anesthesia was less in the group I than in the group II. Except for baseline reading, HR was significantly higher in the atropine group versus the control group. MBP was higher in the atropine group than in the control group in all readings. SV and SVR were similar in both groups. Neonatal outcomes were equivalent in both groups.
Conclusion
Pre-spinal atropine was effective in preventing post-spinal bradycardia and minimized CO reduction in patients undergoing elective cesarean delivery under spinal anesthesia.

DOI

TEJA-2023-0145

Keywords

atropine, cardiac output, Caesarean delivery, ELECTRICAL CARDIOMETRY, Spinal anesthesia

Authors

First Name

Amin M.

Last Name

Alansary

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Mohamed Mourad

Last Name

Ali

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Minatallah Ali

Last Name

Elshafie

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

Volume

39

Article Issue

1

Related Issue

51163

Issue Date

2023-12-01

Receive Date

2023-06-10

Publish Date

2023-12-31

Page Start

571

Page End

578

Print ISSN

1110-1849

Online ISSN

1687-1804

Link

https://egja.journals.ekb.eg/article_387949.html

Detail API

https://egja.journals.ekb.eg/service?article_code=387949

Order

387,949

Publication Type

Journal

Publication Title

Egyptian Journal of Anaesthesia

Publication Link

https://egja.journals.ekb.eg/

MainTitle

Impact of pre-spinal atropine on post spinal hemodynamic and cardiac output measured by electrical cardiometry in cesarean delivery, a randomized controlled trial

Details

Type

Article

Created At

21 Dec 2024