Beta
387918

Evaluation of Ambu-Aura-i laryngeal mask as a conduit for endotracheal intubation. A comparison with Air-Q intubating laryngeal airway in adult surgical patients

Article

Last updated: 31 Dec 2024

Subjects

-

Tags

-

Abstract

Background
Supraglottic airway devices (SGA) are used as primary devices or conduits for endotracheal intubation with normal or difficult airway. The purpose of this study was to assess how the Ambu-Aura-i laryngeal mask would act as a conduit for endotracheal intubation compared to the Air-Q Intubating Laryngeal airway in adult patients in operating room.
Methods
Fifty-four adult patients scheduled for elective procedures under general anaesthesia were divided into air-Q and Aura-i groups. The ease and time of insertion, the number of insertion attempts, the airway leak pressure, the duration of fiberoptic endotracheal intubation, the grade of the fibre-optic laryngoscopic view, and the time to remove the device were noted.
Results
Comparing the Aura-i group to the Air-Q group, the Aura-i group had a considerably shorter insertion time and a longer time to remove the device (28.1 ± 3.5 vs 32.7 ± 6.9 sec P-value = 00.4 and 40.7 ± 5.1 vs 32.0 ± 5.4 sec, P-value = 0.001; respectively). Both devices were comparable regarding the number of insertion attempts and the time to insert an endotracheal tube. Compared to the Air-Q group, the Aura-i group’s airway leak pressure was considerably greater (25.9 ± 3.9 vs 23.4 ± 4 CmH2O, respectively, P-value = 0.03). Both groups had comparable fibre-optic laryngoscopic view grades.
Conclusion
The Ambu-Aura-i laryngeal mask and the Air-Q intubating laryngeal airway are efficient conduits for fibre-optic endotracheal intubation in adults with Ambu-Aura-i Laryngeal mask exhibiting advantages in terms of device insertion time and use during mechanical ventilation.

DOI

TEJA-2022-0257

Authors

First Name

Sherif M.

Last Name

Soaida

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Safinaz H.

Last Name

Osman

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Abeer

Last Name

Ahmed

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Dalia

Last Name

Saad

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Mohamed A.

Last Name

Selim

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

Volume

39

Article Issue

1

Related Issue

51163

Issue Date

2023-12-01

Receive Date

2022-12-18

Publish Date

2023-12-31

Page Start

356

Page End

361

Print ISSN

1110-1849

Online ISSN

1687-1804

Link

https://egja.journals.ekb.eg/article_387918.html

Detail API

https://egja.journals.ekb.eg/service?article_code=387918

Order

387,918

Publication Type

Journal

Publication Title

Egyptian Journal of Anaesthesia

Publication Link

https://egja.journals.ekb.eg/

MainTitle

Evaluation of Ambu-Aura-i laryngeal mask as a conduit for endotracheal intubation. A comparison with Air-Q intubating laryngeal airway in adult surgical patients

Details

Type

Article

Created At

21 Dec 2024