Beta
387902

Effectiveness of C-MAC video-stylet versus C-MAC D-blade video-laryngoscope for tracheal intubation in patients with predicted difficult airway: Randomized comparative study

Article

Last updated: 31 Dec 2024

Subjects

-

Tags

-

Abstract

Background
This prospective study was done on patients with suspected difficult airway to compare between C-MAC video-stylet (VS) and D-blade video-laryngoscope for tracheal intubation.
Patients and methodology
Randomization was done on 160 adult patients with anticipated difficulty in intubation for different causes to divide them into two equal groups (VS group and D group). Patients in each group were divided into five categories according to the cause of anticipated intubation difficulty. Duration of intubation, number of attempts, and success intubation rate were recorded. Hemodynamics parameters were measured before intubation as baseline, then after intubation at 1 and 5 min.
Results
In VS group, intubation time ranged between 23 and 166 s with mean of 53.2 ± 24.19 s and in D group it ranged between 30 and 279 s with mean of 65.5 ± 40.63 s (-value 0.021). This shorter intubation time was not constant in different patient’s categories. The first attempt intubation was successfully done in 68 patients (85%) in VS group versus 61 patients (76.3%) in D group. Hemodynamically, HR and MABP showed significant increase in D group more than in VS group at 1 and 5 min after intubation (-value = 0.001).
Conclusion
Both devices are helpful when there is a risk of difficult intubation. C-MAC VS is a better choice in cases of limited mouth opening and obesity, but in cases of limited cervical motility, the use of C-MAC D-blade is a better choice with a faster intubation time.

DOI

TEJA-2023-0023

Keywords

C-MAC video - stylet, C-MAC D-blade, difficult airway, intubation time

Authors

First Name

Yasser Mohamed

Last Name

Osman

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Rehab Abd El-Raof

Last Name

Abd El-Aziz

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

Volume

39

Article Issue

1

Related Issue

51163

Issue Date

2023-12-01

Receive Date

2023-01-30

Publish Date

2023-12-31

Page Start

233

Page End

240

Print ISSN

1110-1849

Online ISSN

1687-1804

Link

https://egja.journals.ekb.eg/article_387902.html

Detail API

https://egja.journals.ekb.eg/service?article_code=387902

Order

387,902

Publication Type

Journal

Publication Title

Egyptian Journal of Anaesthesia

Publication Link

https://egja.journals.ekb.eg/

MainTitle

Effectiveness of C-MAC video-stylet versus C-MAC D-blade video-laryngoscope for tracheal intubation in patients with predicted difficult airway: Randomized comparative study

Details

Type

Article

Created At

21 Dec 2024