Beta
387607

Harmonic scalpel versus electrocautery in axillary lymph-node dissection in patients with breast cancer: a prospective randomized study

Article

Last updated: 29 Dec 2024

Subjects

-

Tags

-

Abstract

Background
Multiple techniques have been used for tissue dissection and achieving hemostasis during breast surgery, including harmonic scalpel and electrocautery. However, there are some conflicting results between different studies regarding some parameters like operative time and seroma formation. This study aims to compare between the previous two techniques for axillary lymph-node dissection in breast cancer patients.
Patients and methods
We recruited 98 cases diagnosed with breast cancer for this prospective randomized study. The cases were divided into two groups according to the dissection technique, harmonic, and electrocautery groups. Intraoperative and postoperative parameters were compared between the two groups.
Results
Both patient and tumor criteria were comparable between the two groups. However, both operative time and blood loss showed a significant decrease with harmonic use. In addition, the same device led to a significant decrease in drain discharge and early drain removal. However, no significant difference was noted regarding the number of dissected lymph nodes and the duration of hospitalization. As regards postoperative complications, it showed no significant differences between the study groups.
Conclusion
Harmonic scalpel is more beneficial compared with the conventional electrocautery technique. It is associated with shorter operative time, less blood loss, less postoperative pain, less drainage discharge, and early drain removal.

DOI

10.4103/ejs.ejs_185_21

Keywords

axillary lymph-node dissection, breast cancer, Electrocautery, Harmonic Scalpel

Authors

First Name

Hossam Ramadan

Last Name

Moussa

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Tamer M.

Last Name

Elmahdy

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Amir Fawzy

Last Name

Abdelhamid

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

Volume

40

Article Issue

4

Related Issue

51153

Issue Date

2021-10-01

Receive Date

2021-06-05

Publish Date

2021-10-01

Page Start

1,180

Page End

1,186

Print ISSN

1110-1121

Online ISSN

1687-7624

Link

https://ejsur.journals.ekb.eg/article_387607.html

Detail API

https://ejsur.journals.ekb.eg/service?article_code=387607

Order

387,607

Publication Type

Journal

Publication Title

The Egyptian Journal of Surgery

Publication Link

https://ejsur.journals.ekb.eg/

MainTitle

Harmonic scalpel versus electrocautery in axillary lymph-node dissection in patients with breast cancer: a prospective randomized study

Details

Type

Article

Created At

21 Dec 2024