Beta
384319

Comparison of drug-coated balloon versus plain balloon angioplasty for autogenous hemodialysis access dysfunction: A prospective cohort study

Article

Last updated: 29 Dec 2024

Subjects

-

Tags

-

Abstract

Background: Both drug-coated balloon (DCB) angioplasty and conventional plain balloon angioplasty can be implemented
to treat hemodialysis dysfunction. The present study aims to compare the safety and efficacy of these two approaches by
conducting a prospective cohort study.
Objective: The study aims to evaluate DCB safety and arteriovenous fistula effectiveness in relation to plain balloon for
hemodialysis access dysfunction.
Patients and Methods: All patients were allocated and blinded, randomized during the period of study into two groups.
Group A: patients were operated on with drug-eluting balloons (n=40), while group B patients were operated on with
standard balloons (n=40). The results of both groups were analyzed and compared.
Results: DCB was used to treat 40 patients (mean age, 49.48±8 years) with failed arteriovenous fistulas. These patients
were compared with a reference group of 40 patients, mean age 50.6±9.4 years, who had just simple balloon PTA.
Regular PTA balloons were used to dilate every case of stenosis. In the research group, DCBs were used for medication
delivery after hemodynamic success (30% residual stenosis). The 6-, 12-, and 24-month follow-up intervals were used.
Comparisons were made between primary, primary assisted, and secondary patency. At 0.05, the statistical significance
was established. When primary patency was evaluated between the two groups, it was shown that the study group (DCB)
had substantially greater results at 12 months (75.0 vs. 52.5%; P=0.036) and 24 months (52.5 vs. 30.0%; P=0.041). At 24
months, there were notable variations in secondary patency (52.5 vs. 30.0; P=0.041).
Conclusion: In addition to lowering the number of interventions and improving target lesion primary patency over the
first 12 and 24 months, DCB also improves secondary patency at the 24-month mark.

DOI

10.21608/EJSUR.2024.303935.1119

Keywords

Arteriovenous fistula, drug-coated balloon angioplasty, hemodialysis dysfunction, plain balloon angioplasty

Authors

First Name

Mohamed

Last Name

Mohamed

MiddleName

I.

Affiliation

Department of Vascular Surgery, Faculty of Medicine, Ain Shams University, Cairo, eGYPT

Email

-

City

-

Orcid

-

First Name

Ahmed

Last Name

Eldeeb

MiddleName

A.

Affiliation

Department General Surgery, Faculty of Medicine, Menoufia University, Menoufia, Egypt

Email

ahmed_eldeeb@icloud.com

City

-

Orcid

-

First Name

Ayman

Last Name

Hassan

MiddleName

A.M.

Affiliation

Department of Vascular Surgery, Faculty of Medicine, Ain Shams University, Cairo, eGYPT

Email

-

City

-

Orcid

-

First Name

Mina

Last Name

Basta

MiddleName

G.Z.

Affiliation

Department of aVascular Surgery, Faculty of Medicine, Ain Shams University, Cairo, eGYPT

Email

-

City

-

Orcid

-

Volume

43

Article Issue

4

Related Issue

50769

Issue Date

2024-10-01

Receive Date

2024-10-05

Publish Date

2024-10-01

Page Start

1,587

Page End

1,596

Print ISSN

1110-1121

Online ISSN

1687-7624

Link

https://ejsur.journals.ekb.eg/article_384319.html

Detail API

https://ejsur.journals.ekb.eg/service?article_code=384319

Order

384,319

Type

Original Article

Type Code

3,086

Publication Type

Journal

Publication Title

The Egyptian Journal of Surgery

Publication Link

https://ejsur.journals.ekb.eg/

MainTitle

Comparison of drug-coated balloon versus plain balloon angioplasty for autogenous hemodialysis access dysfunction: A prospective cohort study

Details

Type

Article

Created At

21 Dec 2024