Beta
376349

PARTIAL SPLENECTOMY USING RELOADABLE LINEAR STAPLERS IN DOGS

Article

Last updated: 29 Dec 2024

Subjects

-

Tags

-

Abstract

Background: The aim of this study was to test the efficiency and safty of using reloadable linear staplers in partial 
splenectomy. 
Methods: This was an experimental study on dogs. Partial splenectomy was performed in 20 adult mongrel healthy dogs 
using reloadable linear staplers (RL ― 90) [*1]. Another 10 dogs were sham -operated as a control group. The dogs were 
followed up post operatively by close observation and by hematological parameters including erythrocytic count, 
haemoglobin level, packed cell volume (PCV) and total leucoytic count. After one month the dogs were sacrificed and autopsy was performed. 
Results: Intra-operative bleeding was negligible during resection of the spleen and there was no clinical or laboratory 
signs of post operative hemorrhage in all the operated dogs. They all survived for one month without complications. 
Conclusion and Recommendations: The use of stapling technique in partial splenectomy in dogs was quite safe, ensured excellent heamostasis and shortened the time of operation. Nevertheless, due to the specification of the instrument, its application in humans might be suggested to be restricted to those having a thin spleen allows the use of the stapler as in case of young children with localized pathology in their spleen.

DOI

10.21608/ejsur.2001.376349

Authors

First Name

M.

Last Name

Emad Esmat

MiddleName

-

Affiliation

Department of General Surgery, Theoder Bilharz Research Institute

Email

-

City

-

Orcid

-

First Name

M.

Last Name

Abbas

MiddleName

-

Affiliation

Department of General Surgery, Theoder Bilharz Research Institute

Email

-

City

-

Orcid

-

First Name

S.

Last Name

Kishta

MiddleName

-

Affiliation

Department of General Surgery, Theoder Bilharz Research Institute

Email

-

City

-

Orcid

-

First Name

E.

Last Name

M.E sheta

MiddleName

-

Affiliation

Department of Surgery, Anesthesiology and Radiology, Faculty of Veterinary Medicine, Cairo University, Egypt

Email

-

City

-

Orcid

-

Volume

20

Article Issue

3

Related Issue

50030

Issue Date

2001-07-01

Receive Date

2024-08-27

Publish Date

2001-07-01

Page Start

616

Page End

623

Print ISSN

1110-1121

Online ISSN

1687-7624

Link

https://ejsur.journals.ekb.eg/article_376349.html

Detail API

https://ejsur.journals.ekb.eg/service?article_code=376349

Order

376,349

Type

Original Article

Type Code

3,086

Publication Type

Journal

Publication Title

The Egyptian Journal of Surgery

Publication Link

https://ejsur.journals.ekb.eg/

MainTitle

PARTIAL SPLENECTOMY USING RELOADABLE LINEAR STAPLERS IN DOGS

Details

Type

Article

Created At

21 Dec 2024