Subjects
-Tags
-Abstract
Aim: To compare between subareolar and peritumoral injection of methylene blue dye for proper detection
of sentinel lymph in cancer breast.
Method: Eighty female patients with early breast cancer were randomly divided into two equal groups. In
the first group blue dye was injected in the subareolar area. In the second group the dye was injected in the
peritumoral region. Intra-operative identification of sentinel lymph node(s) was done and then all patients
were subjected to complete axillary lymph nodes dissection. Histopathology examination of the tumor and
all axillary lymph nodes including the sentinel node(s) was performed using haematoxylin and eosin stain.
Results: Identification rate of the sentinel node was 100% in group A and 86.7% in group B. False negative
rate was 0% & sensitivity was 100% in both groups. Specificity was 80% in group A and 87.5% in group B.
Positive predictive value was 71.43% and 83.3% in both group A & B. Negative predictive value was 100%
for both groups.
Conclusion: We recommend usage of methylene blue subareolar injection as a safe and accurate technique
for identification of sentinel lymph node in early cancer breast patients.
DOI
10.21608/ejsur.2010.367570
Keywords
SLN identification, Axillary dissection
Authors
MiddleName
-Affiliation
Department of Surgery, Faculty of Medicine, University of Alexandria, Egypt
Email
-City
-Orcid
-MiddleName
-Affiliation
Department of Surgery, Faculty of Medicine, University of Alexandria, Egypt
Email
-City
-Orcid
-MiddleName
-Affiliation
Pathology, Faculty of Medicine, University of Alexandria, Egypt
Email
-City
-Orcid
-Link
https://ejsur.journals.ekb.eg/article_367570.html
Detail API
https://ejsur.journals.ekb.eg/service?article_code=367570
Publication Title
The Egyptian Journal of Surgery
Publication Link
https://ejsur.journals.ekb.eg/
MainTitle
SUBAREOLAR VERSUS PERITUMORAL INJECTION OF METHYLENE BLUE FOR SENTINEL LYMPH NODE DETECTION IN CASES OF EARLY BREAST CANCER