Beta
365004

Different techniques for closure of appendicular stump in laparoscopic appendectomy – are they safe and applicable?

Article

Last updated: 29 Dec 2024

Subjects

-

Tags

-

Abstract

Background
Laparoscopic appendectomy (LA) is globally accepted as a less-invasive surgical approach for acute appendicitis. LA has many advantages over open appendectomy like less postoperative pain, earlier recovery, better cosmetic results, and shorter hospital stay. For appendicular stump closure, there are different techniques: endoligature [including preformed suture loops (endo-loops), extracorporeal sutures using knot pushers, and intracorporeal knot-ligature sutures], bipolar coagulation, endoscopic linear GIA staplers, metal clips, or hem-o-lock.
Aim
To compare among four methods for closure of the appendicular stump regarding their safety, applicability, competence, and complications.
Patients and methods
The study was conducted between December 2017 and March 2021 in Tanta University hospitals. The study included 260 patients with acute appendicitis who were randomly divided into four groups. In the first group, the base of the appendix was secured using intracorporeal knot, extracorporeal sutures using knot pushers in the second group, metallic clip in the third group, and Hem-o-lock clip in the fourth group. The primary outcome was assessment of safety and applicability of appendicular stump closure using four different techniques. Secondary outcomes were operative time, hospital stay time, and surgical outcome.
Results
A total of 260 patients (128 females and 132 males) were enrolled into the study. The mean age in group A was 27.30 ± 8.79 years, in group B was 28.94 ± 12.86 years, in group C was 25.96 ± 10.03 years, and in group D was 26.90 ± 6.07 years. A statistically significant difference was observed among the four groups regarding the time for stump closure (<0.001) and in the operative time (<0.001), as longer operative and stump closure times were reported in group A. No statistically significant difference was found among the four groups concerning superficial wound infection.
Conclusion
Application of all four methods of stump closure is safe, reliable, and applicable and enhances the surgical hand skills.

DOI

10.4103/ejs.ejs_67_22

Keywords

acute appendicitis, Hem-o-lock clip, Laparoscopic appendectomy

Authors

First Name

Ahmed

Last Name

Swelam

MiddleName

-

Affiliation

-

Email

ahmed_swelam81@yahoo.com

City

-

Orcid

-

First Name

Emad M.

Last Name

Sallam

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Tamer M.

Last Name

Elmahdy

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Sherif

Last Name

Elgarf

MiddleName

-

Affiliation

-

Email

elgarfsherif@gmail.com

City

-

Orcid

-

Volume

41

Article Issue

2

Related Issue

48970

Issue Date

2023-01-01

Receive Date

2022-03-09

Publish Date

2023-01-04

Print ISSN

1110-1121

Online ISSN

1687-7624

Link

https://ejsur.journals.ekb.eg/article_365004.html

Detail API

https://ejsur.journals.ekb.eg/service?article_code=365004

Order

365,004

Publication Type

Journal

Publication Title

The Egyptian Journal of Surgery

Publication Link

https://ejsur.journals.ekb.eg/

MainTitle

Different techniques for closure of appendicular stump in laparoscopic appendectomy – are they safe and applicable?

Details

Type

Article

Created At

21 Dec 2024