Beta
364346

Safety and efficacy of infraclavicular arterioarterial chest wall prosthetic loop graft for hemodialysis access: a review of 45 patients

Article

Last updated: 29 Dec 2024

Subjects

-

Tags

-

Abstract

Introduction
With raising the demand for hemodialysis (HD) owing to concomitant increased incidence of nephropathic disease, which has led to associated increased patients’ life expectancy in the past three decades, it becomes necessary to establish a secondary or a tertiary HD vascular access to overcome the exhausted peripheral veins and central venous occlusion.
Aims
Our case study reports midterm (24-month follow-up) results with infraclavicular arterioarterial loop graft and evaluates its efficacy and safety in construction of HD vascular access for patients with end-stage renal disease.
Material and methods
This was a prospective study. From December 2014 to December 2017, 45 patients with end-stage renal disease on chronic HD with exhausted all peripheral and central veins or were considered unsuitable for creation of arteriovenous fistula/graft owing to heart failure underwent arterioarterial chest wall prosthetic graft implantation for creation of HD vascular access. The data analysis was done using SPSS version 20.0 for Windows.
Results
The primary patency rates were 100, 97.7, 93, 77.5, and 73.7% at 6, 9, 12, 18, and 24 months, respectively. The secondary patency rates were 100, 85.7, and 66.6% at 6, 9, and 12 months, respectively, after successful thrombectomy in nine patients. There were 20 (44.4%) secondary variable procedures performed in 18 (40%) patients during follow-up period, with no procedure-related mortality or limb-threatening conditions being documented in our study.
Conclusion
Our case study reports a reasonable midterm patency rate, and complications associated with this pattern of vascular access show that infraclavicular arterioarterial loop grafts are a valid alternative option for complex patients. We advocate the use of this technique in patients with exhausted all vascular access possibilities in both upper extremities with central venous obstruction. We also indicate it in case of patients with cardiac insufficiency who could not tolerate long-term hemodynamic effect of arteriovenous fistula/graft.

DOI

10.4103/ejs.ejs_54_18

Keywords

arterioarterial, cardiac insufficiency, central venous occlusion, Hemodialysis, vascular access

Authors

First Name

Ahmed K.

Last Name

Allam

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Ahmed M.

Last Name

Elmahdi

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

Volume

37

Article Issue

4

Related Issue

48945

Issue Date

2018-10-01

Receive Date

2018-11-28

Publish Date

2018-10-01

Print ISSN

1110-1121

Online ISSN

1687-7624

Link

https://ejsur.journals.ekb.eg/article_364346.html

Detail API

https://ejsur.journals.ekb.eg/service?article_code=364346

Order

364,346

Publication Type

Journal

Publication Title

The Egyptian Journal of Surgery

Publication Link

https://ejsur.journals.ekb.eg/

MainTitle

Safety and efficacy of infraclavicular arterioarterial chest wall prosthetic loop graft for hemodialysis access: a review of 45 patients

Details

Type

Article

Created At