Beta
371474

Ion Chromatographic Determination of Gallium by Mixed Ion Exchanger

Article

Last updated: 05 Jan 2025

Subjects

-

Tags

-

Abstract

A progressing procedure is offered for determining of Gallium at low levels in two geological samples using High
Performance Ion Chromatography technique (HPIC). At the optimum operating conditions determined experimentally,
isocratic elution of gallium was 8mM pyridine-(2,6)-dicarboxylic acid eluent concentration (PDCA) at pH of 4 and flow rate
of 0.7mL/min. Two granite geological samples from Gabal Gatter and Gabal El Sela-Qash Amer area have been applied for
direct determination of gallium by applying the modified method. The method permits the evaluation of gallium without an
external preconcentration or complexing agents.

DOI

10.21608/jbes.2020.371474

Keywords

Determination, gallium, mixed ion exchanger, IC, granite geological samples

Authors

First Name

Entesar Mohamed

Last Name

El Gammal

MiddleName

-

Affiliation

Nuclear Materials Authority, P.O. Box 530 El Maadi, Cairo, Egypt

Email

-

City

-

Orcid

-

Volume

7

Article Issue

4

Related Issue

49590

Issue Date

2020-10-01

Receive Date

2024-08-02

Publish Date

2020-10-01

Page Start

202

Page End

207

Print ISSN

2536-9202

Online ISSN

2356-6388

Link

https://jbes.journals.ekb.eg/article_371474.html

Detail API

https://jbes.journals.ekb.eg/service?article_code=371474

Order

371,474

Type

Original Article

Type Code

3,063

Publication Type

Journal

Publication Title

Journal of Basic and Environmental Sciences

Publication Link

https://jbes.journals.ekb.eg/

MainTitle

Ion Chromatographic Determination of Gallium by Mixed Ion Exchanger

Details

Type

Article

Created At