Beta
347434

Malposition of hemodialysis catheter into arch of aorta

Article

Last updated: 05 Jan 2025

Subjects

-

Tags

-

Abstract

Malpositioning of internal jugular hemodialysis catheter in great artery is rare but a serious complication. Misplacement of a hemodialysis catheter from internal jugular vein in to arch of aorta is presented.
A 28-year-old male patient diagnosed with chronic kidney disease, underwent cannulation using landmark guidance in preparation for dialysis. Chest X-ray revealed malpositioning of the catheter tip piercing the arch of aorta.
During exploration under general anesthesia surgical approach was through neck, to dissect down to the catheter entry into the thorax. The catheter was removed uneventfully.
Although rare, vascular complications following hemodialysis catheter insertion can lead to considerable morbidity and mortality. If any suspicion of arterial injury arises then it is recommended to leave the catheter in situ and seek prompt vascular surgery consultation
The level of experience of the clinician can also reduce the risk of inadvertent arterial placement of central venous catheter. Use of real time ultrasonography may be helpful.

DOI

10.21608/asja.2024.250592.1015

Keywords

Catheter, Central Venous, Hemodialysis, misplacement

Authors

First Name

Sangey

Last Name

Tamang

MiddleName

D

Affiliation

Department of Anesthesiology and Critical Care Medicine, Indira Gandhi Institute of Medical Sciences, Patna 800014, INDIA

Email

sangeymoktan07@gmail.com

City

-

Orcid

0009-0003-3258-6595

First Name

prakash

Last Name

dubey

MiddleName

k

Affiliation

Department of Anesthesiology and Critical Care Medicine, Indira Gandhi Institute of Medical Sciences, Patna 800014, INDIA.

Email

pkdubey@hotmail.com

City

-

Orcid

0000-0002-1732-2634

First Name

Alok

Last Name

Bharti

MiddleName

K

Affiliation

Department of Anesthesiology and Critical Care Medicine, Indira Gandhi Institute of Medical Sciences, Patna 800014, INDIA.

Email

alok.bharti48@gmail.com

City

-

Orcid

0000-0002-3044-0619

Volume

16

Article Issue

1

Related Issue

46864

Issue Date

2024-01-01

Receive Date

2023-11-22

Publish Date

2024-01-01

Page Start

1

Page End

2

Print ISSN

1687-7934

Online ISSN

2090-925X

Link

https://asja.journals.ekb.eg/article_347434.html

Detail API

https://asja.journals.ekb.eg/service?article_code=347434

Order

347,434

Type

Letter to the Editor

Type Code

2,884

Publication Type

Journal

Publication Title

Ain-Shams Journal of Anesthesiology

Publication Link

https://asja.journals.ekb.eg/

MainTitle

Malposition of hemodialysis catheter into arch of aorta

Details

Type

Article

Created At

20 Dec 2024