Background
Operating rooms (OR) are noisy places, and proper control of intraoperative noise is advised by health care organizations to avoid its hazardous effects. Finding a smartphone application to measure and control intraoperative annoying sound is necessary.
Objective
To compare noise levels in Kasr Al Ainy Hospitals’ ORs with the World Health Organization (WHO) recommendations and to investigate their effects on patients.
Methods and material
Forty patients who underwent surgeries under regional anesthesia at six different theaters enrolled in this observational cohort study. Sound was recorded by TM-102 Sound Level Meter and NoiseCapture app simultaneously. They used to capture the maximum (Max) and minimum (Min) values of A-weighting and average (mean) values in decibel (dB). The 1ry outcome was a comparison of the equivalent sound pressure levels (Leq (A)) measured by TM-102 Sound Level Meter with WHO recommendation (i.e., 40 dB).
Results
Mean noise levels in different theaters were far away from the WHO recommendations. The mean (Leq (A)) level measured by TM-102 Sound Level Meter was 73.01 (± 5.74) compared to 72.15 (± 6.57) measured by NoiseCapture. These levels exceeded the WHO recommendation by around 1.8 times. Both tools showed a good correlation with no statistically significant differences in all readings. Four distressed patients (66.7%) reported the obstetric theater as the highest noisy OR (78 dB).
Conclusions
Intraoperative noise levels at Kasr Al Ainy Hospital reached critical values that exceeded the international recommendations. For intraoperative noise monitoring, NoiseCapture smartphone application appeared like a straightforward hand-held software appropriate for this purpose.

DOI

10.1186/s42077-020-00070-1

Keywords

Noise, WHO recommendations, NoiseCapture, sound level meter

Authors

First Name

Hany Mohammed El-Hadi Shoukat

Last Name

Mohammed

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

0000-0003-0736-2218

First Name

Sahar Sayed Ismail

Last Name

Badawy

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Ahmed Ibrahim Hussien

Last Name

Hussien

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Antony Adel Fahmy

Last Name

Gorgy

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

Volume

12

Article Issue

1

Related Issue

44737

Issue Date

2020-01-01

Receive Date

2020-05-06

Publish Date

2020-06-05

Print ISSN

1687-7934

Online ISSN

2090-925X

Link

https://asja.journals.ekb.eg/article_329642.html

Detail API

https://asja.journals.ekb.eg/service?article_code=329642

Order

329,642

Publication Type

Journal

Publication Title

Ain-Shams Journal of Anesthesiology

Publication Link

https://asja.journals.ekb.eg/

MainTitle

Assessment of noise pollution and its effect on patients undergoing surgeries under regional anesthesia, is it time to incorporate noise monitoring to anesthesia monitors: an obs

Details

Type

Article

Created At

20 Dec 2024