After the energy crisis during the 1970s, energy availability became questionable. Hospitality
buildings consume large amounts of energy to provide comfort and several services for guests. Energy efficiency
and renewable energy hold the key to sustainable energy provision and tourism development and represent the
key for energy balance in the hospitality sector of Egypt. This paper aims to minimize energy usage and manage
the effective use of natural resources as wind, to enhance environmental conditions. Employment of passive
design techniques as natural ventilation techniques is proposed as a mitigating measure for the excessive energy
use in hotel buildings. Solar chimney has proven scientifically as one of the effective passive solar-induced
ventilation tools. This study investigates the impact of using different percentages of the glazing part on the
indoor air velocity and indoor operative air temperature based on a number of CFD simulation results.
Investigating a prototype of a five star hotel in Upper Egypt, a base case of three floors hotel building with
repetitive hotel room 4m*8m is proposed with façade designed to include an open terrace and vertical solar
chimney. Within the framework of this study, DesignBuilder software was used for CFD simulation.
Investigating different options for the selected parameter, results show that indoor operative temperatures can be
increased by increasing the glazing percentage, while the age of air can be reduced and the indoor air velocity
can be increased, so it will enhance the ventilation rates

DOI

10.21608/erjsh.2021.227528

Keywords

Hospitality Buildings, Thermal Performance, passive design, Natural Ventilation, Solar Chimney

Authors

First Name

Rana

Last Name

Osama Saad

MiddleName

-

Affiliation

Department of Architecture, Faculty of Engineering, Ain Shams University

Email

-

City

-

Orcid

-

First Name

Morad

Last Name

Abdelkader

MiddleName

-

Affiliation

Department of Architecture, Faculty of Engineering, Ain Shams University

Email

-

City

-

Orcid

-

First Name

Abeer

Last Name

Mohammad Mostafa

MiddleName

-

Affiliation

Department of Architecture, Faculty of Engineering, Ain Shams University

Email

-

City

-

Orcid

-

Volume

49

Article Issue

1

Related Issue

32437

Issue Date

2021-07-01

Receive Date

2022-03-28

Publish Date

2021-07-01

Page Start

197

Page End

208

Print ISSN

3009-6049

Online ISSN

3009-6022

Link

https://erjsh.journals.ekb.eg/article_227528.html

Detail API

https://erjsh.journals.ekb.eg/service?article_code=227528

Order

227,528

Type

Research articles

Type Code

2,276

Publication Type

Journal

Publication Title

Engineering Research Journal (Shoubra)

Publication Link

https://erjsh.journals.ekb.eg/

MainTitle

The Effect of Solar Chimney on the Thermal Performance of Hotel Room in Aswan, Upper Egypt

Details

Type

Article

Created At

23 Jan 2023