Subjects
-Tags
-Abstract
This paper presents an experimental and numerical investigation into web crippling resistance of
unfastened cold formed steel Z-sections subjected to Interior One Flange (IOF). Both Z-sections have stiffened
and unstiffened flanges were studied. This paper presented the results of 12 test specimens considering the IOF
loading condition. A verified finite element models were developed to simulate the experimental tests. An
extended parametric study was carried out based on the verified finite element models. The parametric study
included the different factors affecting the web crippling resistance such as; material yield stress, web thickness,
inside bend radius, web depth and bearing load length to thickness ratios. The web crippling strength according
to the Eurocode EN 1993-1-3 and the North American specification AISI S100-16 were compared to the
experimental and the finite element results. The comparisons showed that the two specs; Eurocode EN 1993-1-3
and AISI S100-16 overestimated the web crippling strength of the studied range of cold formed steel Z-sections.
Modifications were proposed to improve the design standard predicted resistances.
DOI
10.21608/erjsh.2021.227504
Keywords
Web crippling, Cold formed steel, Z section, Interior one flange loading, and Finite element analysis
Authors
Last Name
Saied Refaee Saleh
MiddleName
-Affiliation
Faculty of Engineering (Shoubra), Benha University, Egypt.
Email
-City
-Orcid
-MiddleName
-Affiliation
Faculty of Engineering (Shoubra), Benha University, Egypt.
Email
-City
-Orcid
-Last Name
Abdelmoniem Abdelfattah
MiddleName
-Affiliation
Faculty of Engineering (Shoubra), Benha University, Egypt.
Email
-City
-Orcid
-Last Name
Badawy Badawy Abu-Sena
MiddleName
-Affiliation
Faculty of Engineering (Shoubra), Benha University, Egypt.
Email
-City
-Orcid
-Link
https://erjsh.journals.ekb.eg/article_227504.html
Detail API
https://erjsh.journals.ekb.eg/service?article_code=227504
Publication Title
Engineering Research Journal (Shoubra)
Publication Link
https://erjsh.journals.ekb.eg/
MainTitle
Web crippling strength of Cold Formed Steel Z-Sections Subjected to Interior One Flange Loading.