265156

The accuracy of cerebellar diameter in detection of the expected date of delivery in comparison with femur length in third trimester

Article

Last updated: 05 Jan 2025

Subjects

-

Tags

Healthcare research

Abstract

Background: The cerebellum, the largest part of hind brain, lies in the posterior cranial fossa. In the embryo cerebellum appears at the end of the fifth week as a swelling overriding the fourth ventricle. Assessment of gestational age (G.A.) is important in the management of pregnancy. The aim is to assess the reliability of trans-cerebellum diameter in compare with the femur length in predicting gestational age. Methodology: This is descriptive, cross-sectional study carried out on seventy-one pregnant women with history of reliable menstrual cycles (sure of dates, regular cycles, no history of hormonal contraception at last 6 months, no history of abortion or delivery at last 3 months) and did not suffer from any complications for the mother or fetus, referred for routine ultrasound examination in ultrasound department of El Minia University maternity hospital, FL was used as standard method to estimate gestational age to be compared with the other gestational age that obtained with TCD. Results: among pregnant women in the GA 28-32 and 32-36 weeks, there was non-statistically significant difference between GA as estimated by TCD and as estimated by other assessed fetal biometry (SFH and FL).  we found that TCD can correctly predict GA in early 3rd trimester (28-36 weeks) at cut-off point >34.9 mm with a sensitivity of 94%. Conclusions: The result of the study revealed that is there is no significant difference between gestational age obtained with FL and TCD. The study recommended that the TCD can be used as routine measurement in estimation of the gestational age in the third trimester.
 
Keywords: Gestational Age, Femur Length, Trans-cerebellar Diameter, Third trimester.
 

DOI

10.21608/mjmr.2022.265156

Keywords

Gestational age, femur length, Trans-cerebellar Diameter, Third Trimester

Authors

First Name

Ahmed

Last Name

Sanad

MiddleName

S.

Affiliation

Department of Obstetrics & Gynecology, Faculty of Medicine, Minia University

Email

ahmed.sameer@minia.edu.eg

City

-

Orcid

-

First Name

Ayman

Last Name

Youssef

MiddleName

M.

Affiliation

Department of Obstetrics & Gynecology, Faculty of Medicine, Minia University

Email

ayman_moheb@hotmail.com

City

-

Orcid

-

First Name

Rehab

Last Name

Mohamed Abo Elnaga

MiddleName

E.

Affiliation

Department of Obstetrics & Gynecology, Faculty of Medicine, Minia University

Email

-

City

-

Orcid

-

First Name

Ahmed

Last Name

Mousa

MiddleName

B.

Affiliation

Department of Obstetrics & Gynecology, Faculty of Medicine, Minia University

Email

ahmed.bakr@mu.edu.eg

City

-

Orcid

-

Volume

33

Article Issue

4

Related Issue

36751

Issue Date

2022-10-01

Receive Date

2022-07-31

Publish Date

2022-10-01

Page Start

16

Page End

22

Online ISSN

2682-4558

Link

https://mjmr.journals.ekb.eg/article_265156.html

Detail API

https://mjmr.journals.ekb.eg/service?article_code=265156

Order

265,156

Type

Original Article

Type Code

2,212

Publication Type

Journal

Publication Title

Minia Journal of Medical Research

Publication Link

https://mjmr.journals.ekb.eg/

MainTitle

The accuracy of cerebellar diameter in detection of the expected date of delivery in comparison with femur length in third trimester

Details

Type

Article

Created At

23 Jan 2023