Beta
247006

A comparison between implant retained mandibular overdenture using Bullard abutments versus Ball and socket abutments (Clinical assessment)

Article

Last updated: 05 Jan 2025

Subjects

-

Tags

Healthcare research

Abstract

Background: There are different modalities of treatment for mandibular edentulous. This study aimed to evaluate marginal bone loss in implant retained mandibular overdenture using bullard versus ball and socket abutments clinically. Methods: twelve completely edentulous patients were selected from the Outpatient Clinic of the Prosthodontic department, Minia University, and were randomly allocated to two equal groups Ball & socket and Bullard abutments mandibular overdenture. All patients received 2 implants, 3.5 mm in diameter and 10 mm in length, were inserted in canine region. In the first group, prosthesis was retained by ball and socket attachments while in the second group, prosthesis was retained by Bullard attachment. For each patient in both groups marginal bone loss was assessed clinically by periodontal probe at time of denture delivery, then six and twelve months later. Results: The results showed marginal bone loss in both groups with significant increase in ball and socket group. Conclusions: Within the limitations of this study bullard abutments had advantages over ball & socket in terms of marginal bone loss among all follow up periods.
 
 

DOI

10.21608/mjmr.2022.247006

Keywords

implant mandibular overdentures, Ball & socket attachment, bullard attachment, marginal bone loss

Authors

First Name

Mohamed

Last Name

Faried

MiddleName

S.

Affiliation

Removable Prosthodontics, Faculty of Dentistry, Sinai University- Kantra Branch.

Email

-

City

-

Orcid

-

First Name

Gehan

Last Name

Mohamed

MiddleName

F.

Affiliation

Removable Prosthodontics, Faculty of Dentistry, Minia University

Email

-

City

-

Orcid

-

Volume

30

Article Issue

1

Related Issue

31958

Issue Date

2019-03-01

Receive Date

2022-01-24

Publish Date

2019-03-01

Page Start

73

Page End

79

Online ISSN

2682-4558

Link

https://mjmr.journals.ekb.eg/article_247006.html

Detail API

https://mjmr.journals.ekb.eg/service?article_code=247006

Order

247,006

Type

Original Article

Type Code

2,212

Publication Type

Journal

Publication Title

Minia Journal of Medical Research

Publication Link

https://mjmr.journals.ekb.eg/

MainTitle

A comparison between implant retained mandibular overdenture using Bullard abutments versus Ball and socket abutments (Clinical assessment)

Details

Type

Article

Created At

23 Jan 2023