Beta
195802

Parametric Study of Water Jet Pump Performance

Article

Last updated: 28 Dec 2024

Subjects

-

Tags

Energy Efficiency

Abstract

this paper presents experimental analysis results and Computational Fluid Dynamic (CFD) analysis of a water jet pump. The effect of modifying area ratio has been studied experimentally and numerically. A test rig has been planned to study the jet pump several parts using different dimensions and forms, to give more than one area ratio of the jet pump. The style of Computational Fluid Dynamic provides an origin for quantifying the consequences of operating circumstances on the pump performance. During this article, the performing measurements are administered for four motivating pressures 1, 1.5,2, and 2.5 bar, also three values of area ratio are used, they're area ratio = 0.19, 0.29 and 0.41. The results illustrate and discuss velocity and pressure profiles. The worth of area ratio which provides the highest efficiency was found to be 0.19. The Computational Fluid Dynamic results were found to agree well with actual values obtained from the experimental results.

DOI

10.21608/ijaes.2021.80330.1003

Keywords

Jet pump, experimental, CFD simulation, Area ratio

Authors

First Name

Amr

Last Name

Hassan

MiddleName

-

Affiliation

Mechanical Engineering aswan university

Email

amrhamza1980@gmail.com

City

Aswan

Orcid

-

First Name

M. Shaban

Last Name

Eissa

MiddleName

-

Affiliation

Mechanical Power Eng. Dept., Faculty of Energy Engineering Aswan University Aswan, Egypt

Email

mshaban68@yahoo.com

City

aswan

Orcid

-

First Name

W.

Last Name

Aissa

MiddleName

A.

Affiliation

Mechanical Engineering Department Faculty of Energy Engineering, Aswan University Aswan, Egypt

Email

waessa@energy.aswu.edu.eg

City

-

Orcid

-

Volume

3

Article Issue

2

Related Issue

27603

Issue Date

2021-07-01

Receive Date

2021-04-14

Publish Date

2021-07-01

Page Start

35

Page End

41

Print ISSN

2636-3712

Online ISSN

2636-3720

Link

https://ijaes.journals.ekb.eg/article_195802.html

Detail API

https://ijaes.journals.ekb.eg/service?article_code=195802

Order

2

Type

Original papers

Type Code

1,889

Publication Type

Journal

Publication Title

International Journal of Applied Energy Systems

Publication Link

https://ijaes.journals.ekb.eg/

MainTitle

Parametric Study of Water Jet Pump Performance

Details

Type

Article

Created At

23 Jan 2023