Abstract

Aim of the work: The aim of this in-vitro study was to compare between stress distribution around straight and tilted posterior dental implant with different lengths under removable partial denture using electrical strain gauge.  Methods: Four models representing mandibular unilateral distal extension edentulous area in right side were fabricated from epoxy resin and divided into four groups according to the length and angulation of the implant: Group (A), Single vertical straight implant 8mm length was placed at the second molar region. For Group (B): Single vertical straight implant 10mm length was placed at the second molar region. For Group (C): Single 30o mesially tilted implant 8mm length was placed at the second molar region. For Group (D): Single 30o mesially tilted implant 10mm length was placed at the second molar region. Locator abutment was screwed to the implant and removable partial denture was fabricated for every group. 100 N vertical and 65 N oblique static loads were applied at the central fossa of the second molar artificial tooth in the prosthesis. Strain gauge technology was used to measure the microstrains around peri-implant area. Data were collected, tabulated and statistically analyzed using one-way ANOVA and LSD tests.  Results: The results revealed that the microstrain with vertical and oblique static loads in group (A) similar to group (C) and in group (B) similar to group (D) (with variation in implant angulation but constant length), but the microstrain with vertical and oblique static loads in group (A) more than group (B) and in group (C) more than group (D) (with variation in implant length but constant angulation). Conclusions: The microstrain distribution was quite similar for both vertical and tilted implants but in increased implant length can help reduce the microstrain.  

DOI

10.21608/mjd.2020.200153

Keywords

Locator attachment, Microstrain, Strain gauge, Tilted Implant

Volume

7

Article Issue

4

Related Issue

28241

Issue Date

2020-12-01

Receive Date

2021-10-18

Publish Date

2020-12-01

Page Start

50

Page End

53

Print ISSN

2735-4172

Online ISSN

2812-5479

Link

https://mjd.journals.ekb.eg/article_200153.html

Detail API

https://mjd.journals.ekb.eg/service?article_code=200153

Order

7

Type

Original Article

Type Code

1,715

Publication Type

Journal

Publication Title

Mansoura Journal of Dentistry

Publication Link

https://mjd.journals.ekb.eg/

MainTitle

-

Details

Type

Article

Created At

23 Jan 2023