Beta
275027

Evaluation Of Retention and Assessment of Biting Force Distribution of a Complete Denture Fabricated Using 3D Printed Custom Trays with Arcus Digma Versus Conventional Method (A

Article

Last updated: 28 Dec 2024

Subjects

-

Tags

Prosthodontics

Abstract

Aim: The purpose of this study is to evaluate retention and occlusion of complete dentures fabricated using 3D printed custom trays with the aid of arcus digma in less steps versus conventional method.
Materials and methods: Ten patients were selected to participate in this study. For each one, two complete dentures were constructed, Group I were rehabilitated with a conventional complete denture, while Group II were rehabilitated with a complete denture constructed using 3D designed and printed custom trays with gothic arch tracing of jaw relation with the help of arcus digma.
Results: By comparing the two groups there was a significant difference between them in biting force distribution where (SD) values for biting force difference posteriorly between the right and left posterior segments for centric occlusion was significantly higher for Group I (20.52±7.99) than Group II (14.45±7.33). Anteriorly Group I (27.85±25.68) had significantly higher mean value for biting force distribution than Group II (21.70±23.92). While there was no significant difference between them in retention evaluation where Group II (31.36±2.73) showed higher mean value than Group I (28.95±5.95), yet the difference was not significant.
Conclusion: Within the limitations of this study, it was found that dentures made by using gothic arch technique in taking centric relation by the help of arcus digma was more accurate in occlusion, this means that the force was more evenly distributed on the denture leading to better stability and fewer adjustments. Dentures made using this technique also had retention competent to regular dentures.

DOI

10.21608/asdj.2022.116490.1104

Keywords

Arcus digma, Gothic Arch, Printed Custom Tray

Authors

First Name

Yasmin

Last Name

Dawoud

MiddleName

-

Affiliation

Removable prosthodontics, Faculty of dentistry Ain shams university, Cairo, Egypt

Email

yasmin.hamdy.25816@gmail.com

City

cairo

Orcid

-

First Name

Ahmed

Last Name

Ahmed Shawky

MiddleName

-

Affiliation

Removable Prosthodontics, Faculty of dentistry Ain shams university, Cairo, Egypt

Email

dr-ahmedosama@hotmail.com

City

Cairo

Orcid

0009-0000-0579-2439

First Name

Dina

Last Name

Bahig

MiddleName

Essam

Affiliation

Removable prosthodontics, Faculty of dentistry Ain shams university, Cairo, Egypt

Email

dinaessamrafla@gmail.com

City

cairo

Orcid

0000-0001-8806-679x

Volume

23

Article Issue

3

Related Issue

38298

Issue Date

2021-09-01

Receive Date

2021-02-16

Publish Date

2021-09-01

Page Start

120

Page End

131

Print ISSN

1110-7642

Online ISSN

2735-5039

Link

https://asdj.journals.ekb.eg/article_275027.html

Detail API

https://asdj.journals.ekb.eg/service?article_code=275027

Order

16

Type

Original articles

Type Code

1,638

Publication Type

Journal

Publication Title

Ain Shams Dental Journal

Publication Link

https://asdj.journals.ekb.eg/

MainTitle

Evaluation Of Retention and Assessment of Biting Force Distribution of a Complete Denture Fabricated Using 3D Printed Custom Trays with Arcus Digma Versus Conventional Method (A Cross Over Study)

Details

Type

Article

Created At

23 Jan 2023