Abstract

Purpose: To evaluate the accuracy of two different impression techniques on the fit of screw retained bar in implant assisted overdentures.
Methodology: Ten completely edentulous patients were selected from Removable Prosthodontics Department, AinShams university according to the inclusion and exclusion criteria. All patients received implant assisted mandibular overdenture with a screw retained bar. Two bars were made for each patient by two different impression techniques. In the first technique, open top impression was used to fabricate the screw-retained bar. However, in the second technique intraoral digital impression was used. Passive fit of each bar was then evaluated.
Results: The results of this study showed non statistically significant difference between both impression techniques.
Conclusion: Within the limitations of this study it may be concluded that the results for both impression techniques on the fit of the screw-retained bar in implant assisted overdentures
Keywords: Intra oral scanning, Open top impression, Implant retained overdenture.

DOI

10.21608/asdj.2021.62249.1023

Keywords

Intra oral scanning, Open top impression, implant retained overdenture

Authors

First Name

Bassant

Last Name

Gamal El Din

MiddleName

Sherif

Affiliation

Demonstrator, Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry Ain-Shams University, Cairo, Egypt

Email

bassantsherif@dent.asu.edu.eg

City

cairo

Orcid

0000-0002-1420-2020

First Name

Noha

Last Name

Nawar

MiddleName

-

Affiliation

Associate professor of Oral and Maxillofacial prosthodontics Department, Faculty of Dentistry Ain-Shams University, Cairo, Egypt

Email

noha_nawar@dent.asu.edu.eg

City

-

Orcid

0000-0001-7685-1934

First Name

Ahmed

Last Name

Abdelfattah

MiddleName

-

Affiliation

Lecturer of Oral and Maxillofacial prosthodontics Department, Faculty of Dentistry Ain-Shams University, Cairo, Egypt

Email

ahmedmostafa@dent.asu.edu.eg

City

-

Orcid

0000-0001-9911-7644

Volume

21

Article Issue

1

Related Issue

32104

Issue Date

2021-03-01

Receive Date

2021-02-09

Publish Date

2021-03-01

Page Start

127

Page End

134

Print ISSN

1110-7642

Online ISSN

2735-5039

Link

https://asdj.journals.ekb.eg/article_224428.html

Detail API

https://asdj.journals.ekb.eg/service?article_code=224428

Order

16

Type

Original articles

Type Code

1,638

Publication Type

Journal

Publication Title

Ain Shams Dental Journal

Publication Link

https://asdj.journals.ekb.eg/

MainTitle

Accuracy of Different Impression Techniques on The Fit of Screw-Retained Bar Joining Two Interforaminal Implants

Details

Type

Article

Created At

23 Jan 2023