Abstract

The paper analyses the applicability of seismic base isolation made of elastomeric bearings for the seismic mitigation of architectural heritage buildings. Due to the inestimable cultural and historical significance any remedial measures into such objects must be selected with care and are usually very limited. In an ideal situation only interventions with minimum visual impacts on the object and maximum potential for restoring its cultural values would be implemented. Historical structures were usually not designed accounting seismic hazard and might be seismically more vulnerable as modern buildings. The paper deals with seismic base isolation as a technique for increasing the seismic resistance of architectural heritage buildings made of unreinforced masonry. Typical base isolation devices represent special bearings that are usually installed bellow the foundations of the structure. If the isolation system is properly designed it can eliminate the need for using more invasive retrofit measures and techniques. The paper presents a relatively simple and computationally less demanding technique for the modelling and analysis of regular unreinforced masonry (URM) structures. This technique is based on the equivalent frame approach, while the complex seismic failure mechanism of masonry piers is expressed by a single failure mode interaction surface (an "FMI surface"), taking into account the influence of variation in the pier's vertical loading, and it's bending moment distribution. A single failure mode interaction plastic hinge (an "FMI hinge") for each masonry frame element is introduced by combining specific failure modes, taking into account their minimum envelope. In the final part of the work a case study of using base isolation for the seismic retrofitting of an existing three-story masonry building has been conducted. Some results obtained by the N2 method comparing the damage in fixed based and base isolated variant of the test building demonstrate the potential of used techniques for the seismic protection of masonry heritage buildings.

DOI

10.21608/erjeng.2015.128282

Keywords

Architectural Heritage, Unreinforced masonry, Seismic Base Isolation, failure mode interaction surface

Authors

First Name

Vojko

Last Name

Kilar

MiddleName

-

Affiliation

University of Ljubljana, Faculty of Architecture, Slovenia.

Email

vojko.kilar@fa.uni-lj.si

City

-

Orcid

-

First Name

Simon

Last Name

Petrvočič

MiddleName

-

Affiliation

University of Ljubljana, Faculty of Architecture, Slovenia.

Email

simon.petrovcic@fa.uni-lj.si

City

-

Orcid

-

Volume

1

Article Issue

2015

Related Issue

18753

Issue Date

2015-12-01

Receive Date

2020-12-07

Publish Date

2015-12-01

Page Start

60

Page End

66

Print ISSN

2356-9441

Online ISSN

2735-4873

Link

https://erjeng.journals.ekb.eg/article_128282.html

Detail API

https://erjeng.journals.ekb.eg/service?article_code=128282

Order

6

Type

Research articles

Type Code

1,605

Publication Type

Journal

Publication Title

Journal of Engineering Research

Publication Link

https://erjeng.journals.ekb.eg/

MainTitle

SEISMIC BASE ISOLATION FOR REDUCING SEISMIC RISK OF ARCHITECTURAL HERITAGE BUILDINGS

Details

Type

Article

Created At

23 Jan 2023