Abstract

In the present work dialysis process was examined using two types of easily available low
cost membranes; nylon and polyethylene. The mass transfer through the membranes was
affected by the flow rate of solutions passing by the membrane in parallel flow but with no
consistent pattern. The overall mass transfer coefficient of the membranes was less by 10
times than that published by other authors for commonly used membranes in dialysis
processes. A correlation was developed to predict the mass transfer coefficient and when
compared with experimental data showed acceptable agreement.

DOI

10.21608/jesaun.2014.114978

Authors

First Name

Y.S.

Last Name

Fangary

MiddleName

-

Affiliation

Mechanical power eng. department, Faculty of Eng., Ain Shams University, Cairo – Egypt

Email

-

City

-

Orcid

-

Volume

42

Article Issue

No 2

Related Issue

16852

Issue Date

2014-03-01

Receive Date

2013-10-29

Publish Date

2014-03-01

Page Start

353

Page End

364

Print ISSN

1687-0530

Online ISSN

2356-8550

Link

https://jesaun.journals.ekb.eg/article_114978.html

Detail API

https://jesaun.journals.ekb.eg/service?article_code=114978

Order

7

Type

Research Paper

Type Code

1,438

Publication Type

Journal

Publication Title

JES. Journal of Engineering Sciences

Publication Link

https://jesaun.journals.ekb.eg/

MainTitle

INVESTIGATION OF USING LOW COST MEMBRANES IN DIALYSIS PROCESSES

Details

Type

Article

Created At

23 Jan 2023