Beta
114781

PERFORMANCE STUDY OF GENERATOR AIR COOLERS FOR THE HYDRO-POWER PLANT AT ASWAN HIGH DAM

Article

Last updated: 04 Jan 2025

Subjects

-

Tags

Mechanical, Power, Production, Design and Mechatronics Engineering.

Abstract

This paper presents a comparative experimental study on the performance characteristics of the circulating air coolers for the generators of the hydro-power plant of the High Dam in Aswan. The study considers two different air-water cooler designs of cross flow finned tubes heat exchangers working under varying operating conditions. The circulating air temperatures and the cooling water pressures for twelve coolers in each of the twelve units of the hydro-power plant were measured and analyzed to obtain useful results describing the cooler performance. The experimental results are based on measurements over total time duration of 1008 operating hours covering 42 summer days. The results are discussed to investigate the effects of time variation of the generated power, and the locations of the coolers and the power units on the performance of both cooler designs. The results of the actual fouling factor indicate that both coolers were designed with excess surface area to work well for long periods. The agreement of the experimental results with the commonly used effectiveness empirical relation indicates the proper performance of the working coolers. On the other hand, the discussion of the results showed the malfunction of some coolers due to the blockage of their damaged tubes. The overall performance of the air coolers in most power units of the plant maintains good flow behaviour of the hot air and uniformity of its temperature at levels sufficiently below the normal design temperature range for the generators of most power units.

DOI

10.21608/jesaun.2013.114781

Keywords

Hydro-power generators, Air-water coolers, Cross flow heat exchangers, performance characteristics, and Fouling factor

Authors

First Name

A.

Last Name

Kahoul

MiddleName

-

Affiliation

Hydro-Power Generation Company, Aswan, Egypt

Email

-

City

-

Orcid

-

First Name

H. M.

Last Name

Shafey

MiddleName

-

Affiliation

Mechanical Eng. Dept., Faculty of Engineering, Assiut University, Assiut, Egypt

Email

hamdy.shafei@eng.au.edu.eg

City

-

Orcid

-

First Name

A. K.

Last Name

Abdel-Rahman

MiddleName

-

Affiliation

Mechanical Eng. Dept., Faculty of Engineering, Assiut University, Assiut, Egypt

Email

-

City

-

Orcid

-

Volume

41

Article Issue

No 3

Related Issue

16851

Issue Date

2013-05-01

Receive Date

2013-03-10

Publish Date

2013-05-01

Page Start

1,054

Page End

1,077

Print ISSN

1687-0530

Online ISSN

2356-8550

Link

https://jesaun.journals.ekb.eg/article_114781.html

Detail API

https://jesaun.journals.ekb.eg/service?article_code=114781

Order

15

Type

Research Paper

Type Code

1,438

Publication Type

Journal

Publication Title

JES. Journal of Engineering Sciences

Publication Link

https://jesaun.journals.ekb.eg/

MainTitle

PERFORMANCE STUDY OF GENERATOR AIR COOLERS FOR THE HYDRO-POWER PLANT AT ASWAN HIGH DAM

Details

Type

Article

Created At

23 Jan 2023